Passive heave compensation is a technique used to reduce the influence of waves upon lifting and drilling operations.[1] A simple passive heave compensator (PHC) is a soft spring which utilizes spring isolation to reduce transmissibility to less than 1.[2] PHC differs from AHC by not consuming external power.

Principle

The main principle in PHC is to store the energy from the external forces (waves) influencing the system and dissipate them or reapply them later. Shock absorbers or drill string compensators are simple forms of PHC, so simple that they are normally named heave compensators, while "passive" is used about more sophisticated hydraulic or mechanical systems.

A typical PHC device consists of a hydraulic cylinder and a gas accumulator. When the piston rod extends it will reduce the total gas volume and hence compress the gas that in turn increases the pressure acting upon the piston. The compression ratio is low to ensure low stiffness. A well designed PHC device can achieve efficiencies above 80 percent.[3]

Application

PHC is often used on offshore equipment that is at or linked to the seabed. Not requiring external energy, PHC may be designed as a fail-safe system reducing the wave impact on sub-sea operations.[4] PHC may be used along with active heave compensation to form a semi-active system.[5]

Calculation of PHC

Efficiency for a PHC used during offshore lifting operations

Sketch of system

The PHC device is in this calculation connected to the crane hook. Newton`s second law is used to describe the acceleration of the payload:
(m+mA)y¨=kc(y+Hcosωt)

Where
m - is the mass of the load underneath the PHC device
mA - is the added mass of the load underneath the PHC device
y¨ - is the acceleration of the mass of the load underneath the PHC device
kc - is the stiffness of the PHC device
y - is the vertical position of the mass underneath the PHC device
H - is the wave amplitude
ω - is the angular wave frequency
t - is time

If we ignore the transient solution we will find that the ratio between the amplitude of the load and the wave amplitude is:
AH=kcm+mAω2kcm+mA

To simplify the expression it is common to introduce ω0 as the systems natural frequency, defined as:
ω0=kcm+mA

We then get the following expression for the ratio:
AH=1(ωω0)21

The transmissibility TR is defined as:
TR=|1(ωω0)21|

Finally the efficiency is defined as:
ηPHC=1TR

Calculating PHC stiffness

The stiffness of a PHC device is given by:[6]
kc=p0AS(Cκ1)

Where
p0 - is the gas pressure at equilibrium stroke
A - is the piston area
S - is the stroke length
C - is the compression ratio
κ - is the adiabatic coefficent

The product p0A corresponds to the submerged weight of the payload. As we can see from the expression it is clear that low compression ratios as well as long stroke length gives low stiffness.

References

43 year old Petroleum Engineer Harry from Deep River, usually spends time with hobbies and interests like renting movies, property developers in singapore new condominium and vehicle racing. Constantly enjoys going to destinations like Camino Real de Tierra Adentro.

  1. Passive and Active heave Compensation, Albers, TU Delft
  2. Bob Wilde and Jake Ormond: Subsea Heave Compensators, Deep Offshore Technology 2009
  3. The Engineers Guide Safelink AS
  4. Passive Heave Compensation, www.huismanequipment.com/en/products/heave_compensation/passive_heave_compensation
  5. Passive Heave Compensation of Heavy Modules, Sten Magne Eng Jakobsen, 2008, University of Stavanger [1]
  6. Peter Albers: Motion Control in Offshore and Dredging, Springer, 2010. ISBN 978-9048188024