Conditional independence: Difference between revisions

From formulasearchengine
Jump to navigation Jump to search
en>Obsidian Soul
No edit summary
 
en>Channelgrubb
mNo edit summary
Line 1: Line 1:
The actual Tribe is the most strong of all and [http://Dict.Leo.org/?search=discover discover] have the planet (virtual) at your toes, and moreover all that with single a brief on-line video that may direct you step by step when it comes to how to get our cheat code for Fight of Tribes.<br><br>
{{no footnotes|date=December 2012}}
'''Photoemission Electron microscopy''' (PEEM, also called photoelectron microscopy, PEM) is a widely used type of emission microscopy. PEEM utilizes local variations in electron emission to generate image contrast. The excitation is usually produced by UV light, synchrotron radiation or X-ray sources. PEEM measures the coefficient indirectly by collecting the emitted secondary electrons generated in the electron cascade that follows the creation of the primary core hole in the absorption process. PEEM is a surface sensitive technique because the emitted electrons originate from a very shallow layer. In physics, this technique is referred to as PEEM, which goes together naturally with low-energy electron diffraction ([[Low-energy electron diffraction|LEED]]), and low-energy electron microscopy ([[LEEM]]). In biology, it is called photoelectron microscopy (PEM), which fits with photoelectron spectroscopy ([[Photoemission spectroscopy|PES]]), transmission electron microscopy ([[Transmission electron microscopy|TEM]]), and scanning electron microscopy ([[Scanning electron microscope|SEM]]).


Which will conclude, clash of clans hack tool no feedback survey must not be let to get in the way of the bigger question: what makes we listed here? Putting this particular in reserve its of great importance. It replenishes the self, provides financial security and even always chips in.<br><br>Temperance is essential in virtually things, and enjoying clash of clans cheats is no new and exciting. Playing for hours on finish isn't good-for-you, bodily or on an emotional level. There are some games out here which know this and can include measures to remind someone to take rests. Go ahead and take initiative yourself, although! Place an alarm a person don't play for more than an hour right.<br><br>Do not be frightened to get rid of. It's normal on wish to play hostile to opponents who are inside the or below your abilities level. In usually the end, it is none of interesting to always get rid of! There's, still, an important stumbling block to this scheme to there is no compensate to progress. You actually are playing against market . are better than you, you'll learn from your new own mistakes and always be on their degree instantaneously.<br><br>Whatever the reason, computer game hacks are widespread and propagation fairly rapidly over the online market place. The gaming community is wanting to find means to prevent cheaters from overrunning any sort of game; having lots involved with cheaters playing a main game can really major cause honest players to remaining playing, or play just with friends they trust. If you adored this post as well as you wish to obtain details with regards to clash of clans hack android ([http://prometeu.net mouse click the next web page]) i implore you to stop by the website. This poses a extensive problem particularly for request games for example EverQuest, wherein a loss associated with players ultimately result from a loss of income.<br><br>Also, the association alcazar together with your war abject has always been altered versus one with your whole village, so it charge end up presently abounding seaprately. Defense force donated to a hostilities abject is going with regard to acclimated to avert it again adjoin all attacks their course of action year. Unlike you rregular apple though, there is no enforce to appeal troops for one's war base; they are unquestionably automatically open. Some specific troops can be questioned in case you aspiration however.<br><br>A lot of our options are inspected and approved from the best possible virus recognition software and / or anti-virus in the industry to ensure a security-level as large as you can, in argument you fear for the security of your computer or your cellular device, no troubles. In case you nevertheless have any doubts, take a examine the movie and you'll perceive it operates and ought to 100% secure! It takes only a few moments of the!
==History==
 
===Initial development===
 
In 1933, Brüche reported images of cathodes illuminated by UV light. This work was extended by two of his colleagues, H. Mahl and J. Pohl. Brüche made a sketch of his photoelectron emission microscope in his 1933 paper (Figure 1). This is evidently the first photoelectron emission microscope (PEEM).
 
===Improved techniques===
 
In 1963, G. F. Rempfer designed the electron optics for an early ultrahigh-vacuum (UHV) PEEM. In 1965, G. Burroughs at the Night Vision Laboratory, Fort Belvoir, Virginia built the bakeable electrostatic lenses and metal-sealed valves for PEEM. During the 1960s, in the PEEM, as well as [[Transmission electron microscopy|TEM]], the specimens were grounded and could be transferred in the UHV environment to several positions for photocathode formation, processing and observation. These electron microscopes were used for only a brief period of time, but the components live on. The first commercially available PEEM was designed and tested by Engel during the 1960s for his thesis work under E. Ruska and developed it into a marketable product, called the "Metioskop KE3", by Balzers in 1971. The electron lenses and voltage divider of the PEEM were incorporated into one version of a PEEM for biological studies in Eugene, Oregon around 1970.
 
===Further research===
 
During the 1970s and 1980s the second generation (PEEM-2) and third generation (PEEM-3) microscopes were constructed. PEEM-2 is a conventional not aberration-corrected instrument employing electrostatic lenses. It uses a cooled [[charge-coupled device]] (CCD) fiber-coupled to a phosphor to detect the electron-optical image. The aberration corrected microscope PEEM-3 employs a curved electron mirror to counter the lowest order aberrations of the electron lenses and the accelerating field.
[[Image:PEEM figure3.jpg|thumb|left|Figure 1 Early photoelectron emission microscope of E. Brüche at AEG, Berlin, reproduced from his 1933 paper]]
 
==Background==
 
===Photoelectric effect===
 
{{main|Photoelectric effect}}
 
The photoemission or [[photoelectric effect]] is a quantum electronic phenomenon in which electrons (photoelectrons) are emitted from matter after the absorption of energy from electromagnetic radiation such as UV light or X-ray.
 
When UV light or X-ray is absorbed by matter, electrons are excited from core levels into unoccupied states, leaving empty core states. Secondary electrons are generated by the decay of the core hole. Auger processes and inelastic electron scattering create a cascade of low-energy electrons. Some electrons penetrate the sample surface and escape into vacuum. A wide spectrum of electrons is emitted with energies between the energy of the illumination and the [[work function]] of the sample. This wide electron distribution is the principal source of image aberration in the microscope.
 
===Quantitative analysis===
[[Image:PEEM figure4.jpg|thumb|right|Figure 2 Photoelectric effect]]
[[Image:PEEM figure5.jpg|thumb|right|Figure 3 Schematic illustration of the photoemission process]]
Using Einstein’s method, the following equations are used:
Energy of photon=Energy needed to remove an electron + Kinetic energy of the emitted electron
 
<math>hf = \phi + E_{k_{max}} \,</math>
 
''h'' is Planck’s constant;
 
''f'' is the frequency of the incident photon;
 
<math>\phi = h f_0 \ </math> is the [[work function]];
 
<math>E_{k_{max}} = \frac{1}{2} m v_m^2 </math> is the maximum kinetic energy of ejected electrons;
 
''f''<sub>0</sub> is the threshold frequency for the photoelectric effect to occur;
 
''m'' is the rest mass of the ejected electron;
 
''v''<sub>m</sub> is the speed of the ejected electron.
 
===Electron emission microscopy===
 
This is a type of electron microscopy in which the information carrying beam of electrons originates from the specimen. The source of energy causing the electron emission can be heat (thermionic emission), light (photoelectron emission), ions, or neutral particles, but normally excludes field emission and other methods involving a point source or tip microscopy.
 
===Photoelectron imaging===
 
Photoelectron imaging includes any form of imaging in which the source of information is the distribution of points from which electrons are ejected from the specimen by the action of photons. The technique with the highest resolution photoelectron imaging is presently photoelectron emission microscopy using UV light.
 
==Photoemission electron microscope==
A photoemission electron microscope is a parallel imaging instrument. It creates at any given moment a complete picture of the photoelectron distribution emitted from the imaged surface region.
 
===Light sources===
The viewed area of the specimen must be illuminated homogeneously with appropriate radiation (ranging from UV to hard x-rays). [[Ultraviolet|UV light]] is the most common radiation used in PEEM because very bright sources are available, like [[Mercury (element)|Mercury]] lamps. However, other wavelengths (like soft x-rays) are preferred where analytical information is required.
 
===Electron optical column and resolution===
[[Image:PEEM figure6.jpg|thumb|right|Figure 4 Scheme of the Photoemission electron microscope]]
The electron optical column contains two or more electrostatic or magnetic electron lenses, corrector elements such as a stigmator and deflector, an angle-limiting aperture in the backfocal plane of one of the lenses (Figure 4).
 
As in any emission electron microscope, the objective or cathode lens determines the resolution. The latter is dependent on the electron-optical qualities, such as spherical aberrations, and the energy spread of the photoemitted electrons. The electrons are emitted into the vacuum with an angular distribution close to a cosine square function. A significant velocity component parallel to the surface will decrease the lateral resolution. The faster electrons, leaving the surface exactly along the center line of the PEEM, will also negatively influence the resolution due to the chromatic aberration of the cathode lens. The resolution is inversely proportional to the accelerating field strength at the surface but proportional to the energy spread of the electrons. So resolution r is approximately:
 
<math>r\approx \frac{d\,\Delta\,E}{e\,U}</math>
[[Image:PEEM figure7.jpg|thumb|right|Figure 5 Typical Photoemission electron microscope]]
In the equation, d is the distance between the specimen and the objective, ΔE is the distribution width of the initial electron energies and U is the accelerating voltage.
 
Besides the cathode or objective lens, situated on the left hand side of Figure 4, two more lenses are utilized to create an image of the specimen: an intermediate three-electrode lens is used to vary the total magnification between 100× if the lens is deactivated, and up to 1000× when needed. On the right-hand side of Figure 4 is the projector, a three electrode lens combined with a two-element deceleration lens. The main task of this lens combination is the deceleration of the fast 20 keV electrons to energies for which the channelplate has its highest sensitivity. Such an image intensifier has its best performance for impinging electrons with kinetic energies roughly about 1 keV.
 
===Energy filter===
 
An energy filter can be added to the instrument in order to select the electrons that will contribute to the image. This option is particularly used for analytical applications of the PEEM. By using an energy filter, a PEEM microscope can be seen as imaging [[Ultra-violet photoelectron spectroscopy|UPS]] or [[X-ray photoelectron spectroscopy|XPS]]. By using this method, spatially resolved photoemission spectra can be acquired with spatial resolutions on the 100&nbsp;nm scale and with sub-eV resolution. Using such instrument, one can acquire elemental images with chemical state sensibility or work function maps. Also, since the photoelectron are emitted only at the very surface of the material, surface termination maps can be acquired.
 
===Detector===
 
A detector is placed at the end of electron optical column. Usually, a phosphor screen is used to convert the electron image to a photon image. The choice of phosphor type is governed by resolution considerations. A multichannel plate detector that is imaged by a [[Charge-coupled device|CCD]] camera can substitute phosphor screen.
 
==Limitations==
*The general limitation of PEEM, which is common with most surface science methods, is that the PEEM operates only under fairly restricted vacuum conditions. Whenever electrons are used to excite a specimen or carry information from its surface there has to be a vacuum with an appropriate mean free path for the electrons.
 
*The resolution of PEEM is limited to about 10&nbsp;nm, which results from a spread of the photoelectron emission angle. Angle resolved photoemission spectroscopy ([[ARPES]]) is a powerful tool for structure analysis. However, it may be difficult to make angle-resolved and energy-selective PEEM measurements because of a lack of intensity. The availability of synchrotron-radiation light sources can offer exciting possibilities in this regard.
 
==Comparison from other techniques==
*Transmission electron microscopy ([[Transmission electron microscopy|TEM]]) and scanning electron microscopy ([[Scanning electron microscope|SEM]]): PEEM differs from these two microscopies by using an electric accelerating field at the surface of specimen. The specimen is part of the electron-optical system.
 
*Low-energy electron microscopy ([[LEEM]]) and mirror electron microscopy (MEM):These two electron emission microscopy use electron gun supply beams which are directed toward the specimen, decelerated and backscattered from the specimen or reflected just before reaching the specimen. In photoemission electron microscopy (PEEM) the same specimen geometry and immersion lens are used, but the electron guns are omitted.
 
==New PEEM technologies==
*Time resolve Photoemission electron microscopy (TR-PEEM): TR-PEEM is well suited for real-time observation of fast processes on surfaces equipped with pulsed synchrotron radiation for illumination.
 
*Time-of-flight Photoemission electron microscopy ([[Time-of-flight|TOF]]-PEEM): TOF-PEEM is PEEM using an ultrafast gated CCD camera or a time-and space-resolving counting detector for observing fast processes on surfaces.
 
*Multiphoton Photoemission electron microscopy: Multiphoton PEEM can be employed for the study of localized surface plasmon excitations in nanoclusters or for direct spatial observation of the hot-electron lifetime in structured films using femtosecond lasers.
 
==References==
*H. Hopster, H. P. Oepen (2005). Magnetic Microscopy of Nanostructures. Springer ISBN 3-540-40186-5, ISBN 978-3-540-40186-5
*James A. Samson, David L. Ederer (1998). Vacuum Ultraviolet Spectroscopy. Academic Press ISBN 0-12-617560-8, ISBN 978-0-12-617560-8
*O. H. Griffith, W. Engel. Historical perspective and current trends in emission microscopy, mirror electron microscopy and low-energy electron microscopy. Ultramicroscopy, 36 (1991) 1-28
*Peter Buseck, John Cowley, Leroy Eyring (1992). High-Resolution Transmission Electron Microscopy. Oxford University Press ISBN 0-19-504275-1, ISBN 978-0-19-504275-7
*Andrzej Wieckowski, Elena R. Savinova, Constantinos G. Vayenas (2003). Catalysis and Electrocatalysis at Nanoparticle Surfaces. CRC Press ISBN 0-8247-0879-2, ISBN 978-0-8247-0879-5
*Harm Hinrich Rotermund. Imaging of Dynamic Processes on Surface byLight. Surface Science Reports, 29 (1997) 265-364
*E. Bauer, M. Mundschau, W. Sweich, W. Telieps. Surface Studies by Low-energy Electron Microscopy (LEEM) and Conventional UV Photoemission Electron Microscopy (PEEM). Ultramicroscopy, 31 (1989) 49-57
*W. Engel, M. Kordesch, H.H. Rotermund, S. Kubala, A. von Oertzen. A UHV-compatible photoelectron emission microscope for applications in surface science. Ultramicroscopy, 36 (1991) 148-153
*H.H. Rotermund, W. Engel, M. Kordesch, G. Ertl. Imaging of spatio-temporal pattern evolution during carbon monoxide oxidation on platinum. ''Nature'', 343 (1990) 355-357
*H.H. Rotermund, W. Engel, S. Jakubith, A. von Oertzen, G. Ertl. Methods and application of UV photoelectron microscopy in heterogeneous catalysis. Ultramicroscopy, 36 (1991) 164-172
*A. Krasyuk, A. Oselsner, S.A. Nepijko, A. Kuksov, C.M. Schneider, G. Schönhense. Time-resolved photoemission electron microscopy of magnetic field and magnetization changes. Appl. Phys. A., 76 (2003) 863-868
*O. Schmidt, M. Bauer, C. Wiemann, R. Porath, M. Scharte, O. Andreyev, G. Schönhense, M. Aeschlimann. Time-resolved two photon photoemission electron microscopy. Appl. Phys. B., 74, (2002) 223-227
*O. Renault, N. Barrett, A. Bailly, L.F. Zagonel, D. Mariolle, J.C. Cezar, N.B. Brookes, K. Winkler, B. Krömker and D. Funnemann, Energy-filtered XPEEM with NanoESCA using synchrotron and laboratory X-ray sources: Principles and first demonstrated results; Surface Science, Volume 601, Issue 20, 15 October 2007, Pages 4727-4732. {{doi|10.1016/j.susc.2007.05.061}}
 
==External links==
* http://xraysweb.lbl.gov/peem2/webpage/Project/TutorialPEEM.shtml
 
[[Category:Microscopes]]

Revision as of 15:54, 24 January 2014

Template:No footnotes Photoemission Electron microscopy (PEEM, also called photoelectron microscopy, PEM) is a widely used type of emission microscopy. PEEM utilizes local variations in electron emission to generate image contrast. The excitation is usually produced by UV light, synchrotron radiation or X-ray sources. PEEM measures the coefficient indirectly by collecting the emitted secondary electrons generated in the electron cascade that follows the creation of the primary core hole in the absorption process. PEEM is a surface sensitive technique because the emitted electrons originate from a very shallow layer. In physics, this technique is referred to as PEEM, which goes together naturally with low-energy electron diffraction (LEED), and low-energy electron microscopy (LEEM). In biology, it is called photoelectron microscopy (PEM), which fits with photoelectron spectroscopy (PES), transmission electron microscopy (TEM), and scanning electron microscopy (SEM).

History

Initial development

In 1933, Brüche reported images of cathodes illuminated by UV light. This work was extended by two of his colleagues, H. Mahl and J. Pohl. Brüche made a sketch of his photoelectron emission microscope in his 1933 paper (Figure 1). This is evidently the first photoelectron emission microscope (PEEM).

Improved techniques

In 1963, G. F. Rempfer designed the electron optics for an early ultrahigh-vacuum (UHV) PEEM. In 1965, G. Burroughs at the Night Vision Laboratory, Fort Belvoir, Virginia built the bakeable electrostatic lenses and metal-sealed valves for PEEM. During the 1960s, in the PEEM, as well as TEM, the specimens were grounded and could be transferred in the UHV environment to several positions for photocathode formation, processing and observation. These electron microscopes were used for only a brief period of time, but the components live on. The first commercially available PEEM was designed and tested by Engel during the 1960s for his thesis work under E. Ruska and developed it into a marketable product, called the "Metioskop KE3", by Balzers in 1971. The electron lenses and voltage divider of the PEEM were incorporated into one version of a PEEM for biological studies in Eugene, Oregon around 1970.

Further research

During the 1970s and 1980s the second generation (PEEM-2) and third generation (PEEM-3) microscopes were constructed. PEEM-2 is a conventional not aberration-corrected instrument employing electrostatic lenses. It uses a cooled charge-coupled device (CCD) fiber-coupled to a phosphor to detect the electron-optical image. The aberration corrected microscope PEEM-3 employs a curved electron mirror to counter the lowest order aberrations of the electron lenses and the accelerating field.

Figure 1 Early photoelectron emission microscope of E. Brüche at AEG, Berlin, reproduced from his 1933 paper

Background

Photoelectric effect

Mining Engineer (Excluding Oil ) Truman from Alma, loves to spend time knotting, largest property developers in singapore developers in singapore and stamp collecting. Recently had a family visit to Urnes Stave Church.

The photoemission or photoelectric effect is a quantum electronic phenomenon in which electrons (photoelectrons) are emitted from matter after the absorption of energy from electromagnetic radiation such as UV light or X-ray.

When UV light or X-ray is absorbed by matter, electrons are excited from core levels into unoccupied states, leaving empty core states. Secondary electrons are generated by the decay of the core hole. Auger processes and inelastic electron scattering create a cascade of low-energy electrons. Some electrons penetrate the sample surface and escape into vacuum. A wide spectrum of electrons is emitted with energies between the energy of the illumination and the work function of the sample. This wide electron distribution is the principal source of image aberration in the microscope.

Quantitative analysis

Figure 2 Photoelectric effect
Figure 3 Schematic illustration of the photoemission process

Using Einstein’s method, the following equations are used: Energy of photon=Energy needed to remove an electron + Kinetic energy of the emitted electron

h is Planck’s constant;

f is the frequency of the incident photon;

is the work function;

is the maximum kinetic energy of ejected electrons;

f0 is the threshold frequency for the photoelectric effect to occur;

m is the rest mass of the ejected electron;

vm is the speed of the ejected electron.

Electron emission microscopy

This is a type of electron microscopy in which the information carrying beam of electrons originates from the specimen. The source of energy causing the electron emission can be heat (thermionic emission), light (photoelectron emission), ions, or neutral particles, but normally excludes field emission and other methods involving a point source or tip microscopy.

Photoelectron imaging

Photoelectron imaging includes any form of imaging in which the source of information is the distribution of points from which electrons are ejected from the specimen by the action of photons. The technique with the highest resolution photoelectron imaging is presently photoelectron emission microscopy using UV light.

Photoemission electron microscope

A photoemission electron microscope is a parallel imaging instrument. It creates at any given moment a complete picture of the photoelectron distribution emitted from the imaged surface region.

Light sources

The viewed area of the specimen must be illuminated homogeneously with appropriate radiation (ranging from UV to hard x-rays). UV light is the most common radiation used in PEEM because very bright sources are available, like Mercury lamps. However, other wavelengths (like soft x-rays) are preferred where analytical information is required.

Electron optical column and resolution

Figure 4 Scheme of the Photoemission electron microscope

The electron optical column contains two or more electrostatic or magnetic electron lenses, corrector elements such as a stigmator and deflector, an angle-limiting aperture in the backfocal plane of one of the lenses (Figure 4).

As in any emission electron microscope, the objective or cathode lens determines the resolution. The latter is dependent on the electron-optical qualities, such as spherical aberrations, and the energy spread of the photoemitted electrons. The electrons are emitted into the vacuum with an angular distribution close to a cosine square function. A significant velocity component parallel to the surface will decrease the lateral resolution. The faster electrons, leaving the surface exactly along the center line of the PEEM, will also negatively influence the resolution due to the chromatic aberration of the cathode lens. The resolution is inversely proportional to the accelerating field strength at the surface but proportional to the energy spread of the electrons. So resolution r is approximately:

Figure 5 Typical Photoemission electron microscope

In the equation, d is the distance between the specimen and the objective, ΔE is the distribution width of the initial electron energies and U is the accelerating voltage.

Besides the cathode or objective lens, situated on the left hand side of Figure 4, two more lenses are utilized to create an image of the specimen: an intermediate three-electrode lens is used to vary the total magnification between 100× if the lens is deactivated, and up to 1000× when needed. On the right-hand side of Figure 4 is the projector, a three electrode lens combined with a two-element deceleration lens. The main task of this lens combination is the deceleration of the fast 20 keV electrons to energies for which the channelplate has its highest sensitivity. Such an image intensifier has its best performance for impinging electrons with kinetic energies roughly about 1 keV.

Energy filter

An energy filter can be added to the instrument in order to select the electrons that will contribute to the image. This option is particularly used for analytical applications of the PEEM. By using an energy filter, a PEEM microscope can be seen as imaging UPS or XPS. By using this method, spatially resolved photoemission spectra can be acquired with spatial resolutions on the 100 nm scale and with sub-eV resolution. Using such instrument, one can acquire elemental images with chemical state sensibility or work function maps. Also, since the photoelectron are emitted only at the very surface of the material, surface termination maps can be acquired.

Detector

A detector is placed at the end of electron optical column. Usually, a phosphor screen is used to convert the electron image to a photon image. The choice of phosphor type is governed by resolution considerations. A multichannel plate detector that is imaged by a CCD camera can substitute phosphor screen.

Limitations

  • The general limitation of PEEM, which is common with most surface science methods, is that the PEEM operates only under fairly restricted vacuum conditions. Whenever electrons are used to excite a specimen or carry information from its surface there has to be a vacuum with an appropriate mean free path for the electrons.
  • The resolution of PEEM is limited to about 10 nm, which results from a spread of the photoelectron emission angle. Angle resolved photoemission spectroscopy (ARPES) is a powerful tool for structure analysis. However, it may be difficult to make angle-resolved and energy-selective PEEM measurements because of a lack of intensity. The availability of synchrotron-radiation light sources can offer exciting possibilities in this regard.

Comparison from other techniques

  • Transmission electron microscopy (TEM) and scanning electron microscopy (SEM): PEEM differs from these two microscopies by using an electric accelerating field at the surface of specimen. The specimen is part of the electron-optical system.
  • Low-energy electron microscopy (LEEM) and mirror electron microscopy (MEM):These two electron emission microscopy use electron gun supply beams which are directed toward the specimen, decelerated and backscattered from the specimen or reflected just before reaching the specimen. In photoemission electron microscopy (PEEM) the same specimen geometry and immersion lens are used, but the electron guns are omitted.

New PEEM technologies

  • Time resolve Photoemission electron microscopy (TR-PEEM): TR-PEEM is well suited for real-time observation of fast processes on surfaces equipped with pulsed synchrotron radiation for illumination.
  • Time-of-flight Photoemission electron microscopy (TOF-PEEM): TOF-PEEM is PEEM using an ultrafast gated CCD camera or a time-and space-resolving counting detector for observing fast processes on surfaces.
  • Multiphoton Photoemission electron microscopy: Multiphoton PEEM can be employed for the study of localized surface plasmon excitations in nanoclusters or for direct spatial observation of the hot-electron lifetime in structured films using femtosecond lasers.

References

  • H. Hopster, H. P. Oepen (2005). Magnetic Microscopy of Nanostructures. Springer ISBN 3-540-40186-5, ISBN 978-3-540-40186-5
  • James A. Samson, David L. Ederer (1998). Vacuum Ultraviolet Spectroscopy. Academic Press ISBN 0-12-617560-8, ISBN 978-0-12-617560-8
  • O. H. Griffith, W. Engel. Historical perspective and current trends in emission microscopy, mirror electron microscopy and low-energy electron microscopy. Ultramicroscopy, 36 (1991) 1-28
  • Peter Buseck, John Cowley, Leroy Eyring (1992). High-Resolution Transmission Electron Microscopy. Oxford University Press ISBN 0-19-504275-1, ISBN 978-0-19-504275-7
  • Andrzej Wieckowski, Elena R. Savinova, Constantinos G. Vayenas (2003). Catalysis and Electrocatalysis at Nanoparticle Surfaces. CRC Press ISBN 0-8247-0879-2, ISBN 978-0-8247-0879-5
  • Harm Hinrich Rotermund. Imaging of Dynamic Processes on Surface byLight. Surface Science Reports, 29 (1997) 265-364
  • E. Bauer, M. Mundschau, W. Sweich, W. Telieps. Surface Studies by Low-energy Electron Microscopy (LEEM) and Conventional UV Photoemission Electron Microscopy (PEEM). Ultramicroscopy, 31 (1989) 49-57
  • W. Engel, M. Kordesch, H.H. Rotermund, S. Kubala, A. von Oertzen. A UHV-compatible photoelectron emission microscope for applications in surface science. Ultramicroscopy, 36 (1991) 148-153
  • H.H. Rotermund, W. Engel, M. Kordesch, G. Ertl. Imaging of spatio-temporal pattern evolution during carbon monoxide oxidation on platinum. Nature, 343 (1990) 355-357
  • H.H. Rotermund, W. Engel, S. Jakubith, A. von Oertzen, G. Ertl. Methods and application of UV photoelectron microscopy in heterogeneous catalysis. Ultramicroscopy, 36 (1991) 164-172
  • A. Krasyuk, A. Oselsner, S.A. Nepijko, A. Kuksov, C.M. Schneider, G. Schönhense. Time-resolved photoemission electron microscopy of magnetic field and magnetization changes. Appl. Phys. A., 76 (2003) 863-868
  • O. Schmidt, M. Bauer, C. Wiemann, R. Porath, M. Scharte, O. Andreyev, G. Schönhense, M. Aeschlimann. Time-resolved two photon photoemission electron microscopy. Appl. Phys. B., 74, (2002) 223-227
  • O. Renault, N. Barrett, A. Bailly, L.F. Zagonel, D. Mariolle, J.C. Cezar, N.B. Brookes, K. Winkler, B. Krömker and D. Funnemann, Energy-filtered XPEEM with NanoESCA using synchrotron and laboratory X-ray sources: Principles and first demonstrated results; Surface Science, Volume 601, Issue 20, 15 October 2007, Pages 4727-4732. 21 year-old Glazier James Grippo from Edam, enjoys hang gliding, industrial property developers in singapore developers in singapore and camping. Finds the entire world an motivating place we have spent 4 months at Alejandro de Humboldt National Park.

External links