Generalized eigenvector: Difference between revisions

From formulasearchengine
Jump to navigation Jump to search
en>Frietjes
No edit summary
en>BG19bot
m WP:CHECKWIKI error fix. Broken bracket. Do general fixes if a problem exists. - using AWB (10741)
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
[[File:Hydro quebec meter.JPG|thumb|North American domestic [[analog signal|analog]] electricity meter. ]]
Air Transfer Specialists Darell from Arnprior, usually spends time with pastimes including body building, new launch property singapore and tesla coils. Intends to retire and take the family to many of the noteworthy heritage listed locales in the world like Convent of Christ in Tomar.<br><br>My site: [http://prakrithimitra.in/members/adeli9138/activity/173745/ The Skywoods Progress]
[[File:Transparent Electricity Meter found in Israel.JPG|thumb|Electricity meter with transparent plastic case (Israel).]]
[[File:Hydro Quebec meter solid state.jpg|thumb|North American domestic digital electricity meter.]]
An '''electricity meter''' or '''energy meter''' is a device that measures the amount of [[electric energy]] consumed by a [[House|residence]], [[business]], or an electrically powered device.
 
Electricity meters are typically calibrated in billing units, the most common one being the [[kilowatt hour]] [''kWh'']. Periodic readings of electricity meters establishes billing cycles and energy used during a cycle.
 
In settings when energy savings during certain periods are desired, meters may measure demand, the maximum use of power in some interval. "Time of day" metering allows electric rates to be changed during a day, to record usage during peak high-cost periods and off-peak, lower-cost, periods. Also, in some areas meters have relays for [[demand response]] load shedding during peak load periods.<ref>[http://www.minnkota.com/Pages/loadmana.html E.g., Minnkota Power's Load Management System], accessed 22 August 2009.</ref>
 
== History ==
 
=== Direct current (DC) ===
[[File:DC Electric Meter.JPG|thumb|An Aron type DC electricity meter showing that the calibration was in charge consumed rather than energy.]]
As commercial use of electric energy spread in the 1880s, it became increasingly important that an electric energy meter, similar to the then existing [[gas meter]]s, was required to properly bill customers for the [[electricity pricing|cost of energy]], instead of billing for a fixed number of lamps per month. Many experimental types of meter were developed. [[Thomas Edison|Edison]] at first worked on a [[direct current|DC]] electromechanical meter with a direct reading register, but instead developed an [[electrochemical]] metering system, which used an [[electrolytic cell]] to totalise current consumption. At periodic intervals the plates were removed, weighed, and the customer billed. The electrochemical meter was labor-intensive to read and not well received by customers.
[[File:Reason electricity meter.JPG|thumb|left|A 'Reason' meter]]
An early type of electrochemical meter used in the United Kingdom was the 'Reason' meter.  This consisted of a vertically mounted glass structure with a mercury reservoir at the top of the meter. As current was drawn from the supply, electrochemical action transferred the mercury to the bottom of the column.  Like all other DC meters, it recorded ampere-hours.  Once the mercury pool was exhausted, the meter became an open circuit.  It was therefore necessary for the consumer to pay for a further supply of electricity, whereupon, the supplier's agent would unlock the meter from its mounting and invert it restoring the mercury to the reservoir and the supply. <!-- Reference to follow once I have located it, hopefully with an illustration (copyright permitting)--->
 
In 1885 [[Sebastian Ziani de Ferranti|Ferranti]] offered a mercury motor meter with a register similar to gas meters; this had the advantage that the consumer could easily read the meter and verify consumption.<ref>Graeme Gooday ''The morals of measurement: accuracy, irony,and trust in late Victorian electrical practice'', Cambridge University Press, 2004 ISBN 0-521-43098-4, p 232-241</ref>
The first accurate, recording electricity consumption meter was a [[direct current|DC]] meter by [[Hermann Aron|Dr Hermann Aron]], who patented it in 1883. [[Baron Hirst|Hugo Hirst]] of the British [[General Electric Company plc|General Electric Company]] introduced it commercially into Great Britain from 1888.<ref name="Whyte, 1930" >{{cite book
  |title=Forty Years of Electrical Progress
  |last=Whyte  |first=Adam Gowans
  |year=1930
  |publisher=Ernest Benn  |location=London
  |ref=Whyte, 1930
  |pages=31,'''159'''
}}</ref> Unlike their AC counterparts, DC meters did not measure energy.  Instead they measured [[Electric charge|charge]] in ampere-hours.  Since the voltage of the supply should remain substantially constant, the reading of the meter was proportional to actual energy consumed.  For example: if a meter recorded that 100&nbsp;ampere-hours had been consumed on a 200&nbsp;volt supply, then 20&nbsp;kilowatt-hours of energy had been supplied.  Aron's meter recorded the total charge used over time, and showed it on a series of clock dials.
 
=== Alternating current (AC) ===
The first specimen of the [[alternating current|AC]] kilowatt-hour meter produced on the basis of Hungarian [[Ottó Bláthy]]'s patent and named after him was presented by the [[Ganz]] Works at the Frankfurt Fair in the autumn of 1889, and the first induction kilowatt-hour meter was already marketed by the factory at the end of the same year. These were the first alternating-current watt-hour meters, known by the name of Bláthy-meters.<ref>{{cite web|author=Eugenii Katz |url=http://people.clarkson.edu/~ekatz/scientists/blathy.html |title=Blathy |publisher=People.clarkson.edu |date= |accessdate=2009-08-04| archiveurl = http://web.archive.org/web/20080625015707/http://people.clarkson.edu/~ekatz/scientists/blathy.html| archivedate = June 25, 2008}}</ref> The AC kilowatt hour meters used at present operate on the same principle as Bláthy's original invention.<ref>Ricks, G.W.D. This paper appears in: Electrical Engineers, Journal of the Institution of
Issue Date: March 1896
Volume: 25 Issue: 120
On page(s): 57 - 77
Digital Object Identifier: 10.1049/jiee-1.1896.0005
</ref><ref>The Electrical engineer, Volume 5. (February, 1890)</ref><ref>The Electrician, Volume 50. 1923</ref><ref>Official gazette of the United States Patent Office: Volume 50. (1890)</ref>
Also around 1889, [[Elihu Thomson]] of the  American [[General Electric]] company developed a  recording watt meter (watt-hour meter) based on an ironless commutator motor. This meter overcame the disadvantages of the electrochemical type and could operate on either alternating or direct current.<ref>W. Bernard Carlson, ''Innovation as a Social Process: Elihu Thomson and the Rise of General Electric'', Cambridge University Press, 2003 ISBN 0-521-53312-0, pages 1 and 258</ref>
 
In 1894 [[Oliver Shallenberger]] of the [[Westinghouse Electric Corporation]] applied the induction principle previously used <ref>U.S. Patent 388003</ref> only in AC ampere-hour meters to produce a watt-hour meter of the modern electromechanical form, using an induction disk whose rotational speed was made proportional to the power in the circuit.<ref>Stephen A. Dyer (ed.) ''Survey of instrumentation and measurement''Wiley-IEEE, 2001 ISBN 0-471-39484-X, page 875</ref><ref>[http://watthourmeters.com/westinghouse/shall-watt.html Shallnberger integrating watt meter, with illustration, retrieved 2010 Sep 29]</ref> The Bláthy meter was similar to Shallenberger and Thomson meter in that they are two-phase motor meter.<ref>Institution of Electrical Engineers Radio Section |Issue Date: March 1896|On page(s): 57 - 77|Digital Object Identifier: 10.1049/jiee-1.1896.0005| http://www.archive.org/details/journal06sectgoog and http://ieeexplore.ieee.org/Xplore/login.jsp?url=http%3A%2F%2Fieeexplore.ieee.org%2Fiel5%2F5308791%2F5309105%2F05309109.pdf%3Ftp%3D%26arnumber%3D5309109%26punumber%3D5308791&authDecision=-203</ref>  Although the induction meter would only work on alternating current, it eliminated the delicate and troublesome commutator of the Thomson design. Shallenberger fell ill and was unable to refine his initial large and heavy design, although he did also develop a polyphase version.
 
== Unit of measurement ==
[[File:CommercialElectricityMeter.jpg|thumb|Panel-mounted [[solid state (electronics)|solid state]] electricity meter, connected to a 2 [[Apparent power|MVA]] electricity [[Electrical substation|substation]]. Remote current and voltage sensors can be read and programmed remotely by [[modem]] and locally by [[infra-red]].  The circle with two dots is the infra-red port. Tamper-evident seals can be seen.]]
 
The most common unit of measurement on the electricity meter is the [[kilowatt hour]] [''kWh''], which is equal to the amount of energy used by a load of one [[kilowatt]] over a period of one [[hour]], or 3,600,000 [[joule]]s. Some electricity companies use the [[SI]] [[megajoule]] instead.
 
Demand is normally measured in watts, but averaged over a period, most often a quarter or half hour.
 
[[Reactive power]] is measured in "thousands of [[volt-ampere reactive]]-hours", (kvarh). By convention, a "lagging" or [[Inductance|inductive]] load, such as a motor, will have positive reactive power.  A "leading", or [[capacitive]] load, will have negative reactive power.<ref>''[[IEEE]] Recommended practice for industrial and commercial power systems analysis Standard 399-1997'', IEEE, ISBN 1-55937-968-5 page 47</ref>
 
Volt-amperes measures all power passed through a distribution network, including reactive and actual.  This is equal to the product of root-mean-square volts and amperes.
 
Distortion of the electric current by loads is measured in several ways.  [[Power factor]] is the ratio of resistive (or real power) to volt-amperes.  A capacitive load has a leading power factor, and an inductive load has a lagging power factor. A purely resistive load (such as a filament lamp, heater or kettle) exhibits a power factor of 1. Current harmonics are a measure of distortion of the wave form.  For example, electronic loads such as computer power supplies draw their current at the voltage peak to fill their internal storage elements.  This can lead to a significant voltage drop near the supply voltage peak which shows as a flattening of the voltage waveform. This flattening causes odd harmonics which are not permissible if they exceed specific limits, as they are not only wasteful, but may interfere with the operation of other equipment. Harmonic emissions are mandated by law in EU and other countries to fall within specified limits.
 
===Other units of measurement===
In addition to metering based on the amount of energy used, other types of metering are available.
 
Meters which measured the amount of charge ([[coulomb]]s) used, known as [[Ampere-hour|ampere-hour meters]], were used in the early days of electrification. These were dependent upon the supply voltage remaining constant for accurate measurement of energy usage, which was not a likely circumstance with most supplies.
 
Some meters measured only the length of time for which charge flowed, with no measurement of the magnitude of voltage or current being made. These were only suited for constant-load applications.
 
Neither type is likely to be used today.
 
== Types of meters ==
[[File:ElectricityMeterMechanism.jpg|thumb|Mechanism of [[electromechanical]] [[electromagnetic induction|induction]] meter.<br />
1 - Voltage coil - many turns of fine wire encased in plastic, connected in parallel with load.<br />
2 - Current coil - three turns of thick wire, connected in series with load.<br />
3 - Stator - concentrates and confines magnetic field.<br />
4 - Aluminum rotor disc.<br />
5 - rotor brake magnets.<br />
6 - spindle with worm gear.<br />
7 - display dials - note that the 1/10, 10 and 1000 dials rotate [[clockwise]] while the 1, 100 and 10000 dials rotate counter-clockwise.]]
 
Electricity meters operate by continuously measuring the instantaneous [[voltage]] ([[volt]]s) and [[electric current|current]] ([[ampere]]s) to give [[energy]] used (in [[joules]], kilowatt-hours etc.). Meters for smaller services (such as small residential customers) can be connected directly in-line between source and customer. For larger loads, more than about 200 ampere of load, [[current transformer]]s are used, so that the meter can be located other than in line with the service conductors.  The meters fall into two basic categories, electromechanical and electronic.
 
===Electromechanical meters===
The most common type of electricity meter is the [[electromechanical]] [[electromagnetic induction|induction]] watt-hour meter.<ref>{{cite book
  |last=Jehl  |first=Francis
  |title=Menlo Park Reminiscences
  |year=1941
  |publisher=Kessinger Publishing
  |url=http://books.google.com/?id=OkL1Smk4uiAC&dq
  |isbn=978-0-7661-2648-0
}} p.841</ref><ref>{{cite book
  |title=Magnets and Electric Currents|last=Fleming|first=J.A.
  |year=1914
  |publisher=Spon & Chamberlain  |location=New York
  |url=http://books.google.com/?id=Atw4AAAAMAAJ&pg=PA335
}}, p.&nbsp;335</ref>
 
The electromechanical [[Electromagnetic induction|induction]] meter operates by counting the revolutions of a non-magnetic, but electrically conductive, metal disc which is made to rotate at a speed proportional to the power passing through the meter.  The number of revolutions is thus proportional to the energy usage. The voltage coil consumes a small and relatively constant amount of power, typically around 2 watts which is not registered on the meter.  The current coil similarly consumes a small amount of power in proportion to the square of the current flowing through it, typically up to a couple of watts at full load, which is registered on the meter.
 
The disc is acted upon by two sets of [[induction coil|coils]], which form, in effect, a two phase [[linear induction motor|induction motor]]. One coil is connected in such a way that it produces a [[magnetic flux]] in proportion to the [[voltage]] and the other produces a magnetic flux in proportion to the [[electric current|current]]. The field of the voltage coil is delayed by 90 degrees, due to the coil's inductive nature, and calibrated using a lag coil.<ref>{{cite web
  |url=http://www.usbr.gov/power/data/fist/fist3_10/vol3-10.pdf
  |title=Volume 3-10
  |format=PDF
  |accessdate=2009-08-04
}}</ref> This produces [[eddy current]]s in the disc and the effect is such that a [[force]] is exerted on the disc in proportion to the product of the instantaneous current, voltage and phase angle ([[power factor]]) between them. A [[permanent magnet]] exerts an opposing force proportional to the [[Angular velocity|speed of rotation]] of the disc. The equilibrium between these two opposing forces results in the disc rotating at a speed [[Proportionality (mathematics)|proportional]] to the power or rate of energy usage. The disc drives a register mechanism which counts revolutions, much like the [[odometer]] in a car, in order to render a measurement of the total energy used.
 
The type of meter described above is used on a [[Single-phase electric power|single-phase]] [[alternating current|AC]] supply. Different [[polyphase system|phase configurations]] use additional voltage and current coils.
 
[[File:ThreePhaseElectricityMeter.jpg|thumb|[[Three-phase electric power|Three-phase]] electromechanical induction meter, metering 100 A 240/415 V supply. Horizontal aluminum rotor disc is visible in center of meter]]
 
The disc is supported by a spindle which has a [[gear#Worm|worm gear]] which drives the register. The register is a series of dials which record the amount of energy used. The dials may be of the ''cyclometer'' type, an odometer-like display  that is easy to read where for each dial a single [[Numerical digit|digit]] is shown through a window in the face of the meter, or of the pointer type where a pointer indicates each digit. With the dial pointer type, adjacent pointers generally rotate in opposite directions due to the gearing mechanism.
 
The amount of energy represented by one revolution of the disc is denoted by the symbol Kh which is given in units of watt-hours per revolution.  The value 7.2 is commonly seen.  Using the value of Kh one can determine their power consumption at any given time by timing the disc with a stopwatch.
 
<math>P = {{3600 \cdot Kh } \over t}</math>.
 
Where:
::t = time in seconds taken by the disc to complete one revolution,
::P = power in watts.
 
For example, if Kh = 7.2 as above, and one revolution took place in 14.4 seconds, the power is 1800 watts.  This method can be used to determine the power consumption of household devices by switching them on one by one.
 
Most domestic electricity meters must be read manually, whether by a representative of the [[electricity retailing|power company]] or by the customer. Where the customer reads the meter, the reading may be supplied to the power company by [[telephone]], [[Mail|post]] or over the [[internet]]. The electricity company will normally require a visit by a company representative at least annually in order to verify customer-supplied readings and to make a basic safety check of the meter.
 
In an induction type meter, creep is a phenomenon that can adversely affect accuracy, that occurs when the meter disc rotates continuously with potential applied and the load terminals open circuited. A test for error due to creep is called a creep test.
 
Two standards govern meter accuracy, [[ANSI C12.20]] for North America and IEC 62053.
 
===Electronic meters===
Electronic meters display the energy used on an [[LCD]] or LED display, and some can also transmit readings to remote places. In addition to measuring energy used, electronic meters can also record other parameters of the load and supply such as instantaneous and maximum rate of usage demands, [[voltage]]s, [[power factor]] and [[reactive power]] used etc. They can also support time-of-day billing, for example, recording the amount of energy used during on-peak and off-peak hours.
 
====Solid-state design====
[[File:Solid-state-electricity-meter.jpg|thumb|right|[[Solid state (electronics)|Solid state]] electricity meter used in a home in the [[Netherlands]].]]
[[File:Block Diagram.JPG|thumb|Basic block diagram of an electronic energy meter]]
As in the block diagram, the meter has a power supply, a metering engine, a processing and communication engine (i.e. a [[microcontroller]]), and other add-on modules such as RTC, LCD display, communication ports/modules and so on.
 
The metering engine is given the voltage and current inputs and has a voltage reference, samplers and quantisers followed by an ADC section to yield the digitised equivalents of all the inputs. These inputs are then processed using a [[digital signal processor]] to calculate the various metering parameters such as powers, energies etc.
 
The largest source of long-term errors in the meter is drift in the preamp, followed by the precision of the voltage reference.  Both of these vary with temperature as well, and vary wildly because most meters are outdoors.  Characterising and compensating for these is a major part of meter design.
 
The processing and communication section has the responsibility of calculating the various derived quantities from the digital values generated by the metering engine. This also has the responsibility of communication using various protocols and interface with other addon modules connected as slaves to it.
 
RTC and other add-on modules are attached as slaves to the processing and communication section for various input/output functions. On a modern meter most if not all of this will be implemented inside the microprocessor, such as the real time clock (RTC), LCD controller, temperature sensor, memory and analog to digital converters.
 
==Applications==
 
===Multiple tariff (variable rate) meters===
[[electricity retailing|Electricity retailers]] may wish to charge customers different tariffs at different times of the day to better reflect the costs of generation and transmission. Since it is typically not cost effective to store significant amounts of electricity during a period of low demand for use during a period of high demand, costs will vary significantly depending on the time of day. Low cost generation capacity (baseload) such as nuclear can take many hours to  start, meaning a surplus in times of low demand, whereas high cost but flexible generating capacity (such as gas turbines) must be kept available to respond at a moment's notice (spinning reserve) to peak demand, perhaps being used for a few minutes per day, which is very expensive.
 
Some multiple tariff meters use different tariffs for different amounts of demand. These are usually industrial meters.
 
==== Domestic usage ====
Domestic variable-rate meters generally permit two to three tariffs ("peak", "off-peak" and "shoulder") and in such installations a simple electromechanical time switch may be used. Historically, these have often been used in conjunction with electrical [[storage heater]]s or [[hot water storage]] systems.
 
Multiple tariffs are made easier by time of use (TOU) meters which incorporate or are connected to a [[time switch]] and which have multiple registers.
 
Switching between the tariffs may happen via a radio-activated switch rather than a time switch to prevent tampering with a sealed time switch to obtain cheaper electricity.
 
==== United Kingdom ====
[[File:Economy 7 Meter and Teleswitcher.JPG|thumb|right|[[Economy 7]] Meter and Teleswitcher]]
[[Radio teleswitch|Radio-activated switching]] is common in the UK, with a nightly data signal sent within the longwave carrier of [[BBC Radio 4]], 198&nbsp;kHz.  The time of off-peak charging is usually seven hours between midnight and 7.00am GMT, and this is designed to power [[storage heater]]s and [[immersion heater]]s. In the UK, such tariffs are branded ''[[Economy 7]]'' or ''White Meter''. The popularity of such tariffs has declined in recent years, at least in the domestic market, because of the (perceived or real) deficiencies of storage heaters and the comparatively low cost of [[natural gas]] (although there remain many without the option of gas, whether they are outside the gas supply network or cannot afford the capital cost of a radiator system). An [[Economy 10]] meter is also available, which gives 10 hours of cheap off-peak heating spread out over three timeslots throughout a 24 hour period.  This allows multiple top-up boosts to storage heaters, or a good spread of times to run a wet electric heating system on a cheaper electricity rate.<ref>{{cite web
  |url=http://www.electricityprices.org.uk/economy-10
  |title=Price comparison website
  |accessdate=2010-12-15
}}</ref>
 
Most meters using ''[[Economy 7]]'' switch the entire electricity supply to the cheaper rate during the 7 hour night time period,<ref>{{cite web
  |url=http://www.uswitch.com/gas-electricity/economy-7/#step2
  |title=Uswitch comparison website
  |accessdate=2010-12-15
}}</ref> not just the storage heater circuit. The downside of this is that the daytime rate will be significantly higher, and standing charges may be a little higher too. For instance, normal rate electricity may be 9p per kWh, whereas ''[[Economy 7]]'''s daytime rate might be 14 to 17 p per kWh, but only 5.43p per kWh at night. Timer switches installed on [[washing machine]]s, [[tumble dryer]]s, [[dishwasher]]s and [[immersion heater]]s may be set so that they switch on only when the rate is lower.
 
===Commercial usage===
Large commercial and industrial premises may use electronic meters which record power usage in blocks of half an hour or less. This is because most [[electricity grid]]s have demand surges throughout the day, and the power company may wish to give price incentives to large customers to reduce demand at these times. These demand surges often correspond to meal times or, famously, to advertisements in popular [[television programme]]s.
 
===Appliance energy meters {{anchor|plug load meter}}===
Plug in electricity meters (or "Plug load" meters) measure energy used by individual appliances. There are a variety of models available on the market today but they all work on the same basic principle. The meter is plugged into an outlet, and the appliance to be measured is plugged into the meter.  Such meters can help in [[energy conservation]] by identifying major energy users, or devices that consume excessive [[standby power]]. Web resources can also be used, if an estimate of the power consumption is enough for the research purposes.<ref>[http://www.verdel3c.com/stopwattch/ The Stopwattch Electricity Meter, a free resource and power meter]</ref>  A power meter can often be borrowed from the local power authorities<ref>{{cite web
  |url=http://www.austinutilities.com/pages/residential_audit_watts.asp
  |title=Residential&nbsp;— Home Energy Audit&nbsp;— Watts Up
  |publisher=Austin Utilities
  |accessdate=2009-08-04
}}</ref> or a local public library.<ref>{{cite web
  |url=http://www.mge.com/home/saving/energymeter.htm
  |title=Portable Energy Meter
  |publisher=Mge.com
  |accessdate=2009-08-04
}}</ref><ref>{{cite web
  |url=http://www.linkcat.info/ipac20/ipac.jsp?uri=link%3D1100002%40%212072347%40%211100001%40%211100002&menu=search&profile=dial&index=TL&term=Watts%20up%3F%20%5Benergy%20meter%5D#focus
  |title=LINKcat
  |publisher=Linkcat.info
  |accessdate=2009-08-04
}}</ref>
 
===In-home energy use displays===
{{Main|Home energy monitor}}
A potentially powerful means to [[energy conservation|reduce household energy consumption]] is to provide convenient real-time feedback to users so they can change their energy using behavior. Recently, low-cost energy feedback displays have become available. A study using a consumer-readable meter in 500 Ontario homes by ''[[Hydro One]]'' showed an average 6.5% drop in total electricity use when compared with a similarly sized control group. ''Hydro One'' subsequently offered free power monitors to 30,000 customers based on the success of the pilot.<ref>{{cite web
  |url=http://www.energetics.com/madri/pdfs/ChartwellHydroOneMonitoringProgram.pdf
  |title=CBPHydroOneReprint
  |format=PDF
  |accessdate=2009-08-04
}}</ref>  Projects such as [[Google PowerMeter]], take information from a smart meter and make it more readily available to users to help encourage conservation.<ref name=sfgate >{{cite news
  |author=Verne Kopytoff
  |coauthors=Ryan Kim|title=Google plans meter to detail home energy use
  |url=http://www.sfgate.com/cgi-bin/article.cgi?f=/c/a/2009/02/10/BULM15RHFH.DTL&type=tech
  |work=San Francisco Chronicle
  |date=2009-02-22
  |accessdate=2009-02-11
}}</ref>
 
===Smart meters===
{{Main|Smart meter}}
Smart meters go a step further than simple AMR ([[automatic meter reading]]). They offer additional functionality including a real-time or near real-time reads, [[power outage]] notification, and power quality monitoring. They allow price setting agencies to introduce different prices for consumption based on the time of day and the season.
 
These price differences can be used to reduce peaks in demand (load shifting or peak lopping), reducing the need for additional power plants and in particular the higher polluting and costly to operate natural gas powered peaker plants.{{Citation needed|date=June 2012}} The feedback they provide to consumers has also been shown to cut overall energy consumption.{{Citation needed|date=August 2009}}
 
Another type of smart meter uses [[nonintrusive load monitoring]] to automatically determine the number and type of appliances in a residence, how much energy each uses and when.  This meter is used by electric utilities to do surveys of energy use. It eliminates the need to put timers on all of the appliances in a house to determine how much energy each uses.
 
===Prepayment meters===
[[File:PrepaymentMeter.jpg|thumb|Prepayment meter and [[magnetic stripe]] tokens, from a rented accommodation in the UK. The button labeled '''A''' displays information and statistics such as current tariff and remaining credit. The button labeled '''B''' activates a small amount of emergency credit should the customer run out]]
[[File:London electricity keymeter key.jpg|thumb|A prepayment key]]
The standard business model of electricity retailing involves the electricity company billing the customer for the amount of energy used in the previous month or quarter. In some countries, if the retailer believes that the customer may not pay the bill, a prepayment meter may be installed. This requires the customer to make advance payment before electricity can be used. {{Citation needed|date=June 2013}}If the available credit is exhausted then the supply of electricity is cut off by a [[relay]].
 
In the UK, mechanical prepayment meters used to be common in rented accommodation. Disadvantages of these included the need for regular visits to remove [[cash]], and risk of theft of the cash in the meter.
 
Modern solid-state electricity meters, in conjunction with [[smart card]]s, have removed these disadvantages and such meters are commonly used for customers considered to be a poor [[credit risk]]. In the UK, one system is the [[PayPoint]] network, where rechargeable tokens (Quantum cards for natural gas, or plastic "keys" for electricity) can be loaded with whatever money the customer has available.
 
Recently smartcards are introduced as much reliable tokens that allows two way data exchange between meter and the utility.
 
In [[South Africa]], [[Sudan]] and [[Northern Ireland]] prepaid meters are recharged by entering a unique, encoded twenty digit number using a keypad. This makes the tokens, essentially a slip of paper, very cheap to produce.
 
Around the world, experiments are going on,  especially in developing countries, to test pre-payment systems. In some cases, prepayment meters have not been accepted by customers.  There are various groups, such as the Standard Transfer Specification ([[Standard Transfer Specification|STS]]) association, which promote common standards for prepayment metering systems across manufacturers. Prepaid meters using the STS standard are used in many countries.<ref>http://www.sts.org.za</ref><ref>{{cite news| url=http://economictimes.indiatimes.com/genus-power-infrastructures-ltd/directorsreport/companyid-7916.cms | work=The Times Of India | title=Genus Power Infrastructures Ltd}}</ref><ref>http://www.saeec.org.za/members/conlog</ref>
 
===Time of day metering===
Time of Day metering (TOD), also known as Time of Usage (TOU) or Seasonal Time of Day (SToD), metering involves dividing the day, month and year into tariff slots and with higher rates at peak load periods and low tariff rates at off-peak load periods. While this can be used to automatically control usage on the part of the customer (resulting in automatic load control), it is often simply the customers responsibility to control his own usage, or pay accordingly (voluntary load control). This also allows the [[utilities]] to plan their transmission infrastructure appropriately. See also [[Energy demand management|Demand-side Management]] (DSM).
 
TOD metering normally splits rates into an arrangement of multiple segments including on-peak, off-peak, mid-peak or shoulder, and critical peak.  A typical arrangement is a peak occurring during the day (non-holiday days only), such as from 1 pm to 9 pm Monday through Friday during the summer and from 6:30 am to 12 noon and 5 pm to 9 pm during the winter.  More complex arrangements include the use of critical peaks which occur during high demand periods.  The times of peak demand/cost will vary in different markets around the world.
 
Large commercial users can purchase power by the hour using either forecast pricing or real time pricing. Prices range from we pay you to take it (negative) to $1000/MWh (100 cents/kWh).<ref>[http://www.nyiso.com/public/market_data/zone_maps.jsp Market Data Exchange] Day ahead, Hour ahead and Real time pricing for New York</ref>
 
Some utilities allow residential customers to pay hourly rates, such as Illinois, which uses day ahead pricing.<ref>[http://www2.ameren.com/RetailEnergy/realtimeprices.aspx Ameren Day Ahead Pricing]</ref><ref>{{cite web
  |url=http://www.thewattspot.com/rtsavings.php
  |title=Real Time Pricing
  |publisher=Thewattspot.com
  |date= |accessdate=2009-08-04
}}</ref>
 
===Power export metering===
{{See also|Net metering}}
Many electricity customers are installing their own electricity generating equipment, whether for reasons of economy, [[redundancy (engineering)|redundancy]] or [[green power|environmental reasons]]. When a customer is generating more electricity than required for his own use, the surplus may be exported back to the [[power grid]]. Customers that generate back into the "grid" usually must have special equipment and safety devices to protect the grid components (as well as the customer's own) in case of faults (electrical short circuits) or maintenance of the grid (say voltage on a downed line coming from an exporting customers facility).
 
This exported energy may be accounted for in the simplest case by the meter running backwards during periods of [[Net metering|net export]], thus reducing the customer's recorded energy usage by the amount exported. This in effect results in the customer being paid for his/her exports at the full retail price of electricity. Unless equipped with a detent or equivalent, a standard meter will accurately record power flow in each direction by simply running backwards when power is exported. Where allowed by law, utilities maintain a profitable margin between the price of energy delivered to the consumer and the rate credited for consumer-generated energy that flows back to the grid.
Lately, upload sources typically originate from renewable sources (e.g., [[wind turbine]]s, [[photovoltaic]] cells), or [[gas]] or steam [[turbine]]s, which are often found in [[cogeneration]] systems. Another potential upload source that has been proposed is plug-in hybrid car batteries ([[vehicle-to-grid]] power systems).  This requires a "[[smart grid]]," which includes meters that measure electricity via communication networks that require remote control and give customers timing and pricing options.  Vehicle-to-grid systems could be installed at workplace [[parking lot]]s and garages and at [[park and ride]]s and could help drivers charge their batteries at home at night when [[Energy demand management|off-peak]] power prices are cheaper, and receive bill crediting for selling excess electricity back to the grid during high-demand hours.
 
==Ownership==
Following the [[deregulation]] of electricity supply markets in many countries (e.g., UK), the company responsible for an electricity meter may not be obvious. Depending on the arrangements in place, the meter may be the property of the [[meter Operator]], [[electricity distribution|electricity distributor]], the [[electricity retail|retailer]] or for some large users of electricity the meter may belong to the customer.
 
The company responsible for reading the meter may not always be the company which owns it. Meter reading is now sometimes subcontracted and in some areas the same person may read [[gas meter|gas]], [[water meter|water]] and electricity meters at the same time.
 
==Communication methods==
Remote meter reading is a practical example of [[telemetry]]. It saves the cost of a human meter reader and the resulting mistakes, but it also allows more measurements, and remote provisioning. Many smart meters now include a switch to interrupt or restore service.
 
Historically, rotating meters could report their metered information remotely, using a pair of [[electrical contacts]] attached to a ''KYZ'' line.
 
A KYZ interface is a [[Electrical contacts|Form C]] contact supplied from the meter. In a KYZ interface, the Y and Z wires are switch contacts, shorted to K for a measured amount of energy. When one contact closes the other contact opens to provide count accuracy security.<ref>{{cite web|title=What are KYZ Pulses?|url=http://www.solidstateinstruments.com/newsletters/newsletter%20pages/Mar11/What%20are%20KYZ%20Pulses.htm|publisher=SolidState Instruments - a division of Brayden Automation Corp.|accessdate=22 November 2012}}</ref>  Each contact change of state is considered one pulse. The frequency of pulses indicates the power demand. The number of pulses indicates energy metered.<ref>{{cite book
  |url=http://www2.eei.org/products_and_services/descriptions_and_access/handbook_meterng.htm
  |title=Handbook for Electricity Metering
  |publisher=EEI
}}, see index of current edition</ref>
 
KYZ outputs were historically attached to "totaliser relays" feeding a "totaliser" so that many meters could be read all at once in one place.
 
KYZ outputs are also the classic way of attaching electricity meters to [[programmable logic controller]]s, [[building automation|HVAC]]s or other control systems. Some modern meters also supply a contact closure that warns when the meter detects a demand near a higher [[electricity tariff]],
to improve [[demand side management]].
 
Some meters have an [[open collector]] or IR LED  output that give 32-100 ms pulses for each metered amount of electrical energy, usually 1000-10000 pulses per [[Kilowatt hour|kWh]]. Output is limited to max 27 V DC and 27 mA DC. These outputs usually follow the DIN 43864 standard.
 
Often, meters designed for semi-automated reading have a [[serial port]] on that communicates by [[infrared]] LED through the faceplate of the meter. In some multi-unit buildings, a similar protocol is used, but in a wired bus using a [[serial port|serial]] [[current loop]] to connect all the meters to a single plug. The plug is often near a more easily accessible point.
In the European Union, the most common infrared and protocol is "FLAG", a simplified subset of mode C of [[IEC 61107]]. In the U.S. and Canada, the favoured infrared protocol is [[ANSI C12.18]].  Some industrial meters use a protocol for [[programmable logic controller]]s ([[Modbus]] or [[DNP3]]).
 
One protocol proposed for this purpose is [[DLMS/COSEM]] which can operate over any medium, including serial ports. The data can be transmitted by [[Zigbee]], [[WiFi]], [[telephone line]]s or [[Power line communication|over the power lines themselves]]. Some meters can be read over the internet.  Other more modern protocols are also becoming widely used.
 
Electronic meters now use [[short range device|low-power radio]], [[GSM]], [[GPRS]], [[Bluetooth]], [[IrDA]], as well as [[RS-485]] wired link. The meters can now store the entire usage profiles with time stamps and relay them at a click of a button. The demand readings stored with the profiles accurately indicate the load requirements of the customer. This [[load profile]] data is processed at the utilities for billing and planning purposes.
 
''AMR'' ([[Automatic Meter Reading]]) and ''RMR'' (Remote Meter Reading) describe various systems that allow meters to be checked without the need to send a meter reader out. An electronic meter can transmit its readings by telephone line or radio to a central billing office. Automatic meter reading can be done with [[GSM]] (Global System for Mobile Communications)  modems, one is attached to each meter and the other is placed at the central utility office.
 
== Location ==
[[File:CurrentTransformers.jpg|right|thumb|[[Current transformer]]s used as part of metering equipment for [[three-phase]] 400 A electricity supply. The fourth neutral wire does not require a current transformer because current cannot flow in the neutral without first flowing in metered phase wires. ([[Blondel's theorem]]) ]]
[[File:Dunkin donuts electric power meter in framingham ma shot by brian katt with a canon digital rebel in June of 2006.JPG|thumb|A commercial power meter]]
[[File:Electricity meters in India.JPG|thumb|Electricity meters placed outside the homes of residents in a common place, which is accessible only for the department staff and concerned residents]]
[[File:2008-08-12 Technician disconnecting electricity for nonpayment.jpg|thumb|A [[Duke Energy]] technician removes the tamper-proof seal from an electricity meter at a residence in [[Durham, North Carolina]]]]
 
The location of an electricity meter varies with each installation. Possible locations include on a [[utility pole]] serving the property, in a street-side cabinet (meter box) or inside the premises adjacent to the [[consumer unit]] / [[distribution board]]. Electricity companies may prefer external locations as the meter can be read without gaining access to the premises but external meters may be more prone to [[vandalism]].
 
[[Current transformer]]s permit the meter to be located remotely from the current-carrying conductors. This is common in large installations. For example a [[Electrical substation|substation]] serving a single large customer may have metering equipment installed in a cabinet,  without bringing heavy cables into the cabinet.
 
== Customer drop and metering equation ==
Since electrical standards vary in different regions, "customer drops" from the grid to the customer also vary depending on the standards and the type of installation.  There are several common types of connections between a grid and a customer.  Each type has a different ''metering equation.''
 
Customer supplies may be single-phase or three-phase. In the United States and Canada, [[split phase|three-wire single phase]] is common for residential and small commercial customers. Three phase supplies may be three wire, or four wire (with a system neutral). [[Blondel's theorem]] states that for any system with N current-carrying conductors, that N-1 measuring elements are sufficient to measure electrical energy. This indicates that different metering is needed, for example, for a three-phase three-wire system than for a three-phase four-wire (with neutral) system.
 
In North America, it is common for electricity meters to plug into a standardised socket outdoors, on the side of a building. This allows the meter to be replaced without disturbing the wires to the socket, or the occupant of the building. Some sockets may have a bypass while the meter is removed for service. The amount of electricity used without being recorded during this small time is considered insignificant when compared to the inconvenience which might be caused to the customer by cutting off the electricity supply.  Most electronic meters in North America use a serial protocol, [[ANSI C12.18]].
 
In many other countries the supply and load terminals are in the meter housing itself.  Cables are connected directly to the meter.  In some areas the meter is outside, often on a utility pole.  In others, it is inside the building in a niche.  If inside, it may share a data connection with other meters.  If it exists, the shared connection is often a small plug near the post box.  The connection is often [[EIA-485]] or infra-red with a serial protocol such as [[IEC 62056]].
 
In 2010, networking to meters is rapidly changing.  The most common schemes seem to combine an existing national standard for data (e.g. [[ANSI C12.19]] or [[IEC 62056]]) operating via the [[internet protocol]] with a small circuit board that does either [[powerline communication]], or ties to a digital [[mobile phone]] network.
 
== Tampering and security ==
Meters can be manipulated to make them under-register, effectively allowing power use without paying for it.  This theft or fraud can be dangerous as well as dishonest.
 
Power companies often install remote-reporting meters specifically to enable remote detection of tampering, and specifically to discover energy theft.  The change to smart power meters is useful to stop energy theft.
 
When tampering is detected, the normal tactic, legal in most areas of the USA, is to switch the subscriber to a "tampering" tariff charged at the meter's maximum designed current. At US$ 0.095/kWh, a standard residential 50&nbsp;A meter causes a legally collectible charge of about US$ 5,000.00 per month. Meter readers are trained to spot signs of tampering, and with crude mechanical meters, the maximum rate may be charged each billing period until the tamper is removed, or the service is disconnected.
 
A common method of tampering on mechanical disk meters is to attach magnets to the outside of the meter.  These can add to the drag resistance of the internal disk resistance magnets.
 
Rectified DC loads cause mechanical (but not electronic) meters to under-register. DC current does not cause the coils to make eddy currents in the disk, so this causes reduced rotation and a lower bill.
 
Some combinations of capacitive and inductive load can interact with the coils and mass of a rotor and cause reduced or reverse motion.
 
All of these effects can be detected by the electric company, and many modern meters can detect or compensate for them.
 
The owner of the meter normally secures the meter against tampering.  Revenue meters' mechanisms and connections are sealed.  Meters may also measure VAR-hours (the reflected load), neutral and DC currents (elevated by most electrical tampering), ambient magnetic fields, etc.  Even simple mechanical meters can have mechanical flags that are dropped by magnetic tampering or large DC currents.
 
Newer computerised meters usually have counter-measures against tampering. AMR (Automated Meter Reading) meters often have sensors that can report opening of the meter cover, magnetic anomalies, extra clock setting, glued buttons, inverted installation, reversed or switched phases etc.
 
Some tampers bypass the meter, wholly or in part. Safe tampers of this type normally increase the neutral current at the meter. Most split-phase residential meters in the United States are unable to detect neutral currents. However, modern tamper-resistant meters can detect and bill it at standard rates.<ref>Teridian Semiconductors Application Note, "Antitamper Features Enabled by the 71M6511" The 71M6511 is a single chip metering device widely used in computerised meters.</ref>
 
Disconnecting a meter's neutral connector is unsafe because shorts can then pass through people or equipment rather than a metallic ground to the generator.
 
A [[phantom loop]] connection via an earth ground is often much higher resistance than the metallic neutral connector. Even in these cases, metering at the substation can alert the operator to tampering. Substations, inter-ties, and transformers normally have a high-accuracy meter for the area served.  Power companies normally investigate discrepancies between the total billed and the total generated, in order to find and fix power distribution problems.  These investigations are an effective method to discover tampering.
 
Power thefts are often connected with indoor marijuana [[grow operation]]s.  Narcotics detectives associate abnormally high power usage with the lighting such operations require.<ref>{{cite book|title=James Bong's Ultimate SpyGuide to Marijuana|url=http://books.google.co.uk/books?id=w8N4DwMb19oC&pg=PA235&dq=meter+bypass+marijuana&hl=en&ei=iOB2TqbqKpDB8QP_rdXzDQ&sa=X&oi=book_result&ct=result&resnum=3&ved=0CDoQ6AEwAg#v=onepage&q&f=false|pages=234–242|chapter=Theft of power}}</ref> Indoor marijuana growers aware of this are particularly motivated to steal electricity simply to conceal their usage of it.
 
=== Privacy issues ===
The introduction of [[Automatic meter reading|advanced meters]] in residential areas has produced additional privacy issues that may affect ordinary customers.  These meters are often capable of recording energy usage every 15, 30 or 60 minutes.  In some meters real time usage is transmitted on an IR light,  that can be viewed with Night Vison viewers.  These can be used for surveillance, revealing information about people's possessions and behavior.<ref>{{cite journal
  |url=http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=31557
  | title =  Residential energy monitoring and computerized surveillance via utility power flows | author =  Hart, G.W.
  | journal = Technology and Society Magazine, IEEE
  |date=June 1989
  | volume = 8 | issue = 2
  | pages = 12–16
  | doi = 10.1109/44.31557
}}</ref>  For instance, it can show when the customer is away for extended periods.  [[Nonintrusive load monitoring]] gives even more detail about what appliances people have and their living and use patterns.
 
A more detailed and recent analysis of this issue was performed by the [[Illinois Security Lab]].<ref>[http://seclab.illinois.edu/trustworthy-cyber-infrastructure-for-power-tcip/attested-metering Attested Metering project website]</ref>
 
== See also ==
{{portal|Energy}}
 
* [[AEP meter label format]]
* [[Blondel's theorem]]
* [[Electricity distribution]]
* [[Electricity generation]]
* [[Energy management software]]
* [[Energy monitoring and targeting]]
* [[Fixed bill]]
* [[Meter Operator]]
* [[Plug load]]
* [[Too cheap to meter]]
* [[Universal Metering Interface]] (UMI)
* [[Utility submeter]]
* [[Zellweger off-peak]]
 
== Notes ==
{{reflist|2}}
 
== References ==
{{refbegin}}
*"Handbook for Electricity Metering" by The Edison Electric Institute—The Bible of electricity meters, continuously updated since electricity was discovered.
{{refend}}
 
== External links ==
{{Commons category|Electricity meters (kWh)}}
* [http://www.magnet.fsu.edu/education/tutorials/java/electricmeter/index.html Electricity Meter - Interactive Java Tutorial] National High Magnetic Field Laboratory
* [http://www.usbr.gov/power/data/fist/fist3_10/vol3-10.pdf Watt-Hour Meter Maintenance and Testing]
* [http://watthourmeters.com/history.html A brief history of meter companies and meter evolution]
* [http://www.watthourmeters.com/ Photos and descriptions of historic and modern North American electricity meters]
* [http://powermetrix.com/wordpress/wp-content/uploads/2013/01/GLEMS%202012%20-%20metering%20vs%20billing%20accuracy_RSH.pdf Billing Vs. Metering Accuracy]
* [http://books.google.com/books?id=oyQDAAAAMBAJ&pg=RA1-PA107&dq=popular+science+1947+L-15A&hl=en&ei=1EXWTNPjGpGlnQeY0YSwCQ&sa=X&oi=book_result&ct=result&resnum=1&ved=0CDAQ6AEwAA#v=onepage&q&f=true '' "How Electric Meters Work" '', March 1947, Popular Science]
{{Electrical and electronic measuring equipment}}
 
{{DEFAULTSORT:Electricity Meter}}
[[Category:Electric power]]
[[Category:Electric power distribution]]
[[Category:Measuring instruments]]
[[Category:Energy measurement]]

Latest revision as of 22:34, 12 January 2015

Air Transfer Specialists Darell from Arnprior, usually spends time with pastimes including body building, new launch property singapore and tesla coils. Intends to retire and take the family to many of the noteworthy heritage listed locales in the world like Convent of Christ in Tomar.

My site: The Skywoods Progress