'''Lorentz force velocimetry'''<ref name="ThessPRL"/> (LFV) is a noncontact electromagnetic flow measurement technique. LFV is particularly suited for the measurement of velocities in liquid metals like steel or aluminium and is currently under development for metallurgical applications.The measurement of flow velocities in hot and aggressive liquids such as liquid aluminum and molten glass constitutes one of the grand challenges of industrial fluid mechanics. Apart of liquids, LFV can also be used to measure the velocity of solid materials as well as for detection of micro-defects in their structures. | |||
A Lorentz force velocimetry system is called Lorentz force flowmeter (LFF). A LFF measures the integrated or bulk [[Lorentz force]] resulting from the interaction between a liquid metal in motion and an applied magnetic field. In this case the characteristic length of the magnetic field is of the same order of magnitude as the dimensions of the channel. It must be addressed that in the case where localized magnetic fields are used, it is possible to perform local velocity measurements and thus the term Lorentz force velocimeter is used. | |||
== Introduction== | |||
The use of magnetic fields in flow measurement date back to 19th century, when in 1832 [[Michael Faraday]] attempted to determine the velocity of the [[Thames River|River Thames]]. Faraday applied a method in which a flow (the river flow) is exposed to a magnetic field (earth magnetic field) and the induced voltage is measured using two electrodes across the same flow. This method is the basis of the one of most successful commercial application in flow metering known as the inductive flowmeter. The theory of such devices has been developed and comprehensively summarized by Prof. J. A. Shercliff<ref name="Shercliff">Arthur J. Shercliff: Theory of Electromagnetic Flow Measurement. Cambridge University Press, ISBN 978-0-521-33554-6.</ref> in early 1950s. While inductive flowmeters are widely used for flow measurement in fluids at room temperatures such as beverages, chemicals and waste water, they are not suited for flow measurement of media such as hot, aggressive or for local measurements where surrounding obstacles limit access to the channel or pipe. Since they require electrodes to be inserted into the fluid, their use is limited to applications at temperatures far below the melting points of practically relevant metals. | |||
The Lorentz force velocimetry was invented by the A. Shercliff. However, it did not find practical application in these early years up until recent technical advances; in manufacturing of rare earth and non rare-earth strong permanent magnets, accurate force measurement techniques, multiphysical process simulation software for [[Magnetohydrodynamics|magnetohydrodynamic]] (MHD) problems that this principle could be turned into a feasible working flow measurement technique. LFV is currently being developed for applications in metallurgy<ref name="Kolesnikov2011">Y. Kolesnikov, C. Karcher, A. Thess, Lorentz Force Flowmeter for Liquid Aluminum: Laboratory Experiments and Plant Tests (in German), Metall. Mat. Trans. B 42B (2011) pp. 241-250., doi:10.1007/s11663-011-9477-6</ref> as well as in other areas.<ref name="TUI">http://www.tu-ilmenau.de/lorentz-force/</ref> | |||
Based on theory introduced by Shercliff there have been several attempts to develop flow measurement methods which do not require any mechanical contact with the fluid,.<ref name="Priede2011">J. Priede, D. Buchenau., G. Gerbeth, Contactless Electromagnetic Phase-Shift Flowmeter for Liquid Metals, Measur. Sci. Tech. 22 (2011) 055402,2011</ref><ref name="Thess2007"/> Among them is the eddy current flowmeter which measures flow-induced changes in the electric impedance of coils interacting with the flow. More recently, a non-contact method was proposed in which a magnetic field is applied to the flow and the velocity is determined from measurements of flow-induced deformations of the applied magnetic field,.<ref name="Baumgartl1993">J. Baumgartl, A. Hubert, and G. M¨uller , The use of magnetohydrodynamic effects to investigate fluid flow in electrically conducting melts, Phys. Fluids A 5, 3280 (1993)</ref><ref name="Stefani2004">Stefani F., Gundrum T., Gerbeth G., Contactless inductive flow tomography,Phys Rev E 70,056306 (2004)</ref> | |||
== Principle and Physical interpretation== | |||
[[File:LFV.png|right|thumb|400px|Fig. 1 : Working principle of LFV. (a) An electrically conductive fluid is exposed to a magnetic field. (b) The magnetic field induces eddy currents inside the fluid. (c) The eddy currents give rise to a secondary magnetic field. (d) A braking force on the fluid results,which is matched by an accelerating force on the magnet.]] | |||
The principle of Lorentz force velocimetry is based on measurements of the [[Lorentz force]] that occurs due to the flow of a conductive fluid under the influence of a variable [[magnetic field]]. According to [[Electromagnetic induction|Faraday's law]], when a metal or conductive fluid moves through a magnetic field, [[eddy current]]s generate there by [[electromotive force]] in zones of maximal magnetic field gradient (in the present case in the inlet and outlet zones). [[Eddy current]] in its turn creates induced magnetic field according to [[Ampère's circuital law|Ampère's law]]. The interaction between eddy currents and total magnetic field gives rise to Lorentz force that breaks the flow. By virtue of [[Newton's laws of motion|Newton's third law]] "actio=reactio" a force with the same magnitude but opposite direction acts upon its source - permanent magnet. Direct measurement of the magnet's reaction force allows to determine fluid's velocity, since this force is proportional to flow rate. The Lorentz force used in LFV has nothing to do with magnetic attraction or repulsion. It is only due to the eddy currents whose strength depends on the electrical conductivity, the relative velocity between the liquid and the permanent magnet as well as the magnitude of the magnetic field. | |||
So, when a liquid metal moves across magnetic field lines, the interaction of the magnetic field (which are either produced by a current-carrying coil or by a permanent magnet) with the induced eddy currents leads to a Lorentz force (with density <math> \vec{f} = \vec{j} \times \vec{B} </math>) which brakes the flow. The Lorentz force density is roughly | |||
<center> <math> | |||
f \sim \sigma v B^2 | |||
</math> </center> | |||
where <math> \sigma </math> is the [[Electrical resistivity and conductivity|electrical conductivity]] of the fluid, <math> v </math> its velocity, and <math> B </math> the magnitude of the magnetic field. This fact is well known and has found a variety of applications. This force is proportional to the velocity and conductivity of the fluid, and its measurement is the key idea of LFV. With the recent advent of powerful rare earth permanent magnets (like [[Neodymium magnet|NdFeB]], [[Samarium–cobalt magnet|SmCo]] and other kind of magnets) and tools for designing sophisticated systems by permanent magnet the practical realization of this principle has now become possible. | |||
The primary magnetic field <math> \vec{B}\left(\vec{r}\right) </math> can be produced by a permanent magnet or a primary current <math> \vec{J}\left(\vec{r}\right) </math> (see Fig. 1). The motion of the fluid under the action of the primary field induces eddy currents which are sketched in figure 3. They will be denoted by <math> \vec{j}\left(\vec{r}\right) </math> and are called secondary currents. The interaction of the secondary current with the primary magnetic field is responsible for the Lorentz force within the fluid | |||
<center> <math> | |||
\vec{F}_f = \int _f \vec{j} \times \vec{B} d^3\vec{r} | |||
</math> </center> | |||
which breaks the flow. | |||
The secondary currents create a magnetic field <math>\vec{b}\left(\vec{r}\right)</math>, the secondary magnetic field. The interaction of the primary electric current with the secondary magnetic field gives rise to the Lorentz force on the magnet system | |||
<center><math> | |||
\vec{F}_m = \int _m \vec{J} \times \vec{b} d^3\vec{r} | |||
</math></center> | |||
The reciprocity principle for the Lorentz force velocimetry states that the electromagnetic forces on the fluid and on the magnet system have the same magnitude and act in opposite direction, namely | |||
<center> <math> | |||
\vec{F}_m = - \vec{F}_f | |||
</math> </center> | |||
The general scaling law that relates the measured force to the unknown velocity can be derived with reference to the simplified situation shown in Fig. 2. Here a small permanent magnet with dipole moment <math> m</math> is located at a distance <math> L </math> above a semi-infinite fluid moving with uniform velocity <math> v </math> parallel to its free surface. | |||
[[File:Analyticalmodel.png|right|thumb|Fig. 2 : Spatial distribution of magnetic fields in Lorentz force velocimetry: (a) primary magnetic field <math> \vec{B} </math> and eddy currents <math>\vec{J}</math> produced by a magnetic dipole interacting with a uniformly moving electrically conducting fluid; (b) secondary magnetic field <math>\vec{b}</math> due to the horizontal eddy currents <math> \vec{J} </math>. Adapted from.<ref name="ThessPRL"/>]] | |||
The analysis that leads to the scaling relation can be made quantitative by assuming that the magnet is a point dipole with dipole moment <math> \vec{m} = m \hat{e}_z </math> whose magnetic field is given by | |||
<center> <math> | |||
\vec{B} \left( \vec{R}\right) = \frac{\mu _0}{4 \pi} \left\lbrace 3 \frac{\left( \vec{m} \cdot \vec{R} \right) \vec{R} }{ R^5} - \frac{\vec{m}}{R^3} \right\rbrace | |||
</math> </center> | |||
where <math> \vec{R} = \vec{r} - L \hat{e} _z </math> and <math> R = \mid \vec{R} \mid </math>. Assuming a velocity field <math> \vec{v} = v \hat{e} _x </math> for <math> z < 0 </math>, the eddy currents can be computed from Ohm’s law for a moving electrically conducting fluid | |||
<center> <math> | |||
\vec{J} = \sigma \left( -\nabla \phi + \vec{v} \times \vec{B} \right) | |||
</math> </center> | |||
subject to the boundary conditions <math>J_z=0</math> at <math>z=0</math> and <math>J_z \to 0</math> as <math>z \to 1</math>. First, the scalar electric potential is obtained as | |||
<center> <math> | |||
\phi \left( \vec{r} \right) = - \frac{\mu_0 v m}{4 \pi} \frac{x}{R^3} | |||
</math> </center> | |||
from which the electric current density is readily calculated. They are indeed horizontal. Once they are known, the [[Biot-Savart law]] can be used to compute the secondary magnetic field <math> \vec{b} \left( \vec{r}\right) </math>. Finally, the force is given by | |||
<center> <math> | |||
\vec{F} = \left( \vec{m} \cdot \nabla \right) \vec{b} | |||
</math> </center> | |||
where the gradient of <math>\vec{b}</math> has to be evaluated at the location of the dipole. For the problem at hand all these steps can be carried out analytically without any approximation leading to the result | |||
<center> <math> | |||
F = \frac{\mu_0^2 \sigma v m^2}{128 \pi L^3}\hat{e}_z | |||
</math> </center> | |||
This provides us with the estimate | |||
<center> <math> | |||
F \sim \mu_0^2 \sigma v m^2 L^{-3} | |||
</math> </center> | |||
== Conceptual setups == | |||
Lorentz force flowmeters are usually classified in several main conceptual setups. Some of them designed as static flowmeters where the magnet system is at rest and one measures the force acting on it. Alternatively, they can be designed as rotary flowmeters where the magnets are arranged on a rotating wheel and the spinning velocity is a measure of the flow velocity. Obviously, the force acting on a Lorentz force flowmeter depends both on the velocity distribution and on the shape of the magnet system. This classification depends on the relative direction of the magnetic field that is being applied respect to the direction of the flow. In Figure 3 one can distinguish diagrams of the '''longitudinal''' and the '''transverse''' Lorentz force flowmeters. | |||
[[File:Trans longit.png|center|thumb|400px|Fig. 3 : Principle sketch of Lorentz force velocimetry: arrangement of the coil (a) and structure of the primary magnetic field (b) for a longitudinal flux flowmeter. (c, d) Same for a transverse flux flowmeter. Adapted from.<ref name="Thess2007">A. Thess et al., Theory of the Lorentz force flowmeter, 2007 New J. Phys. 9 299</ref>]] | |||
It is important to mention that even that in figures only a coil or a magnet are sketched, the principle holds for both. | |||
'''Rotary LFF''' consists of a freely rotating permanent magnet<ref name="Priede2010">J. Priede, D. Buchenau., G. Gerbeth, Single-Magnet Rotary Flowmeter for Liquid Metals, J. Appl. Phys. 110 (2010) pp. 03451., doi:10.1063/1.3610440</ref> (or an array of magnets mounted on a flywheel as shown in figure 4), which is magnetized perpendicularly to the axle it is mounted on. When such a system is placed close to a duct carrying an electrically conducting fluid flow, it rotates so that the driving torque due to the eddy currents induced by the flow is balanced by the braking torque induced by the rotation itself. The equilibrium rotation rate varies directly with the flow velocity and inversely with the distance between the magnet and the duct. In this case it is possible to measure either the torque on the magnet system or the angular velocity at which the wheel spins. | |||
[[File:RotLFV.png|center|thumb|300px|Fig. 4 : A simplified sketch of the rotary LFV. Adapted from.<ref name="ThessPRL">Thess, A., Votyakov, E. and Kolesnikov, Y. Lorentz Force Velocimetry. Phys. Rev. Lett. 96, 2006</ref>]] | |||
== Practical applications == | |||
LFV is sought to be extended to all fluid or solid materials, providing that they are electrically conductors. As shown before, the Lorentz force generated by the flow depend linearly on the conductivity of the fluid. Typically, the electrical conductivity of molten metals is of the order of <math>10^6 ~ S/m</math> so the Lorentz force is in the range of some ''mN''. However, equally important liquids as glass melts and electrolytic solutions a have a conductivity of <math>\sim ~ 1 ~ S/m </math> giving rise to a Lorentz force of the order of micronewtons or even smaller. | |||
{{multiple image | |||
| footer = Fig. 5 : A) Liquid metals, B) electrolytes, and C) solid bodies. Adapted from.<ref name="TUI"/> | |||
| align = center | |||
| direction = horizontal | |||
| width = 400 | |||
| image1 = A EN Beschriftungen.jpg | |||
| image2 = B EN Beschriftungen.jpg | |||
| image3 = C EN Beschriftungen.jpg | |||
}} | |||
=== High Conducting media: liquid or solid metals === | |||
Among different possibilities to measure the effect on the magnet system, it has been successfully applied those based on the measurement of the deflection of a parallel spring under an applied force.<ref name="Heinecke2012">C. Heinicke et al., Interaction of a small permanent magnet with a liquid metal duct flow. | |||
Journal of Applied Physics (2012) 112</ref> Firstly using a strain gauge and then recording the deflection of a quartz spring with an interferometer, in whose case the deformation is detected to within 0.1 nm. (Fig. 5 A). | |||
=== Low Conducting media: Electrolytic solution or glass melts === | |||
[[File:PendulumScheme.png|right|thumb|Fig. 6 : Schematic of the noncontact Lorentz force flowmeter used in the experiments: (a) A turbulent flow of salt water (with Reynolds numbers roughly between <math> 3.2 \cdot 10^{4}</math> and <math> 1.3 \cdot 10^{5}</math>) is exposed to the magnetic field generated by a lightweight permanent-magnet system hanging on a four-wire pendulum. The displacement of the pendulum is measured using an interferometer as sketched in (b): 1 – He-Ne-Laser, 2 – beam splitter, 3 – reference corner cube reflector, 4 – photo detector, and 5 – measurement corner cube reflector. Adapted from.<ref name="Wegfrass2012">Wegfrass, A. et al., A universal noncontact flowmeter for liquids. Applied Physics Letters, | |||
100 (2012)</ref>]] | |||
Recent advance in LFV made it possible for metering flow velocity of media which has very low electroconductivity, particularly by varying parameters as well as using some state-of-art force measurement devices enable to measure flow velocity of [[Conductivity (electrolytic)|electrolyte solutions with conductivity]] that is 10<sup>6</sup> times smaller than that for the liquid metals. There are variety of industrial and scientific applications where noncontact flow measurement through opaque walls or in opaque liquids is desirable. Such applications include flow metering of chemicals, food, beverages, blood, aqueous solutions in the pharmaceutical industry, molten salts in solar thermal power plants,<ref name="Herrmann">U. Herrmann, B. Kelly, and H. Price, Energy 29, 883–893 (2004)</ref> and high temperature reactors <ref name="Forsberg">C. W. Forsberg, P. F. Peterson, and P. S. Pickard, Nucl. Technol. 144, 289 (2003)</ref> as well as glass melts for high-precision optics.<ref name="LangeandLoch">U. Lange and H. Loch, “Instabilities and stabilization of glass pipe flow” in Mathematical Simulation in Glass Technology, Schott Series on Glass and Glass Ceramics, edited by D. Krause and H. Loch (Springer Verlag, 2002)</ref> | |||
A noncontact flowmeter is a device that is neither in mechanical contact with the liquid nor with the wall of the pipe in which the liquid flows. Noncontact flowmeters are equally useful when walls are contaminated like in the processing of radioactive materials, when pipes are strongly vibrating or in cases when portable flowmeters are to be developed. If the liquid and the wall of the pipe are transparent and the liquid contains tracer particles, optical measurement techniques,<ref name="Tropea">C. Tropea, A. L. Yarin, and J. F. Foss, Handbook of Experimental Fluid Mechanics, Springer-Verlag, GmbH, 2007</ref><ref name="Durst">F. Durst, A. Melling, and J. H. Whitelaw, Principles and Practice of Laser-Doppler Anemometry, 2nd ed. Academic, London, 1981</ref> are effective enough tool to perform noncontact measurements. However, if either the wall or the liquid are opaque as is often the case in food production, chemical engineering, glass making, and metallurgy, very few possibilities for noncontact flow measurement exist. | |||
Up to date there have been two successfully tested prototypes of metering flow velocity, both prototypes are based on deflection measurements of pendulum-like setups (Fig. 5 B). One of the experimental facilities consists of two high power (410 mT) magnets made of [[Neodymium magnet|NdFeB]] suspended by thin wires on both side of channel thereby creating magnetic field perpendicular to the fluid flow, here deflection is measured by interferometer system,<ref name="Wegfrass2">Wegfrass, A. et al. Flow rate measurement of weakly conducting fluids using Lorentz force velocimetry Meas. Sci.Technol. 23 105307 (2012), http://stacks.iop.org/MST/23/105307</ref><ref name="Diethold 2012"/> (see Figures 6 a). The second setup consists of state-of-art weighting balance system from which is being hanged optimized magnets on the base of Halbach array system. While the total mass of both magnet systems | |||
are equal (1 kg), this system induces 3 times higher system response due to arrangement of individual elements in the array and it’s interaction with predefined fluid profile. Here use of very sensitive force measuring devices is desirable, since flow velocity is being converted from the very tiny detected Lorentz Force. This force in combination with unavoidable dead weight <math> F_G</math> of the magnet (<math> F_G = m\cdot g </math>) is around <math> F/F_G = 10^{-7} </math>. | |||
[[File:EFC Balance.jpg|right|thumb|Fig. 7 : Measurement principle, deflected pan carrier: <math> F_{M} </math>-measurement force, <math> F_{G} </math>-gravity, <math> F_{C} </math>-force due to spring constant, <math> c_{s} </math>-spring constant, <math>l_{p}</math>-length of beams, a -deflection of pan carrier, <math> a_{ab} </math>-deflection of lever, <math> \alpha </math> -deflection angle, <math> m_{0} </math>-dead load, <math> g </math> -gravitational acceleration. Adapted from <ref name="Diethold 2012">C. Diethold and F. Hilbrunner, Force measurement of low forces in combination with high dead loads by the use of electromagnetic force compensation, Meas. Sci. Technol. 23, | |||
074017 (2012), http://iopscience.iop.org/0957-0233/23/7/074017/</ref>]] | |||
=== Lorentz force sigmometry === | |||
[[File:LOFOS.png|right|thumb|Fig. 8 : LOFOS working principle.]] | |||
Lorentz force sigmometry (LOFOS)<ref name="Uhlig2012">Uhlig, R. P., Zec, M., Ziolkowski, M., Brauer, H. and Thess, A. 2012 Lorentz force sigmometry: A contactless method for electrical conductivity measurements. Journal of Applied Physics, 111</ref> is a contactless method for measuring the thermophysical properties of materials, no matter whether it is a fluid or a solid body. The precise measurements of electrical value, density, viscosity, thermal conductivity and surface tension of molten metals are in great importance in industry applications. One of the major problems in the experimental measurements of the thermophysical properties at high temperature (>1000 K) in the liquid state is the problem of chemical reaction between the hot fluid and the electrical probes. | |||
The basic equation for calculating the electrical conductivity is derived from the equation that links the mass flow rate <math> \dot{m} </math> and Lorentz force <math> F </math> generated by magnetic field in flow: | |||
<center> <math> | |||
\dot{m} \left(t \right) = \frac{K}{\Sigma} F \left(t \right) \quad | |||
</math> </center> | |||
where <math> \Sigma = \frac{\sigma}{\rho} </math> is the specific electrical conductivity equals to the ratio of the electrical conductivity <math> \sigma </math> and the mass density of fluid <math> \rho </math>. <math> K </math> is a calibration factor that depends on the geometry of the LOFOS system. | |||
From equation above the cumulative mass during operating time is determined as | |||
<center> <math> | |||
M=\int _{t1}^{t2} \dot{m} \left(t \right) dt = \frac{K}{\Sigma} \int _{t1}^{t2} F \left(t \right) dt = \frac{K}{\Sigma} \tilde{F} \quad , | |||
</math> </center> | |||
where <math> \tilde{F} </math> is the integral of Lorentz force within the time process. From this equation and considering the specific electrical conductivity formula, one can derive the final equation to compute the electrical conductivity for the fluid, in the form | |||
<center> <math> | |||
\sigma = \rho K \frac{\tilde{F}}{M} \quad . | |||
</math> </center> | |||
=== Time-of-flight Lorentz force velocimetry === | |||
[[File:ToFLFV2.jpg|right|thumb|Fig. 9 : Time-of-flight working principle. Taken from <ref name="Jian2012"/>]] | |||
Time-of-flight Lorentz force velocimetry,<ref name="Jian2012">Jian, D. and Karcher, C. 2012 Electromagnetic flow measurements in liquid metals using time-of-flight Lorentz force velocimetry. Measurement Science and Technology, 23</ref><ref name="Vire2010">A. Viré, B. Knaepen, and A. Thess, Lorentz force velocimetry based on time-of-flight measurements, Phys. Fluids 22, 125101 (2010)</ref> is intended for contactless determination of flow rate in conductive fluids. It can be successfully used even in case when such material properties as electrical conductivity or density are not precisely known under specific outer conditions. The last reason makes time-of-flight LFV especially important for industry application. According to time-of-flight LFV (Fig. 9) two coherent measurement systems are mounted on a channel one by one. The measurement is based on getting of cross-correlating function of signals, which are registered by two magnetic measurement’s system. Every system consists of permanent magnet and force sensor, so inducing of Lorentz force and measurement of the reaction force are made simultaneously. Any cross-correlation function is useful only in case of qualitative difference between signals and for creating the difference in this case turbulent fluctuations are used. Before reaching of measurement zone of a channel liquid passes artificial vortex generator that induces strong disturbances in it. And when such fluctuation-vortex reaches magnetic field of measurement system we can observe a peak on its force-time characteristic while second system still measures stable flow. Then according to the time between peaks and the distance between measurement system observer can estimate mean velocity and, hence, flow rate of the liquid by equation: | |||
<center> <math> | |||
Q_{flow} = k \frac{D}{\tau} | |||
</math> </center> | |||
where <math> D </math> is the distance between magnet system, <math> \tau </math> the time delay between recorded peaks, and <math> k </math> is obtained experimentally for every specific liquid, as shown in figure 9. | |||
== Lorentz force eddy current testing == | |||
[[File:LET.png|right|thumb|Fig. 10 : LET working principle. Adapted from <ref name="Zec2013">M. Zec et al., Fast Technique for Lorentz Force Calculations in Nondestructive Testing Applications, COMPUMAG 2013, Budapest, Hungary</ref>]] | |||
A different, albeit physically closely related challenge is the detection of deeply lying flaws and inhomogeneities in electrically conducting solid materials. | |||
In the traditional version of eddy current testing an alternating (AC) magnetic field is used to induce eddy currents inside the material to be investigated. If the material contains a crack or flaw which make the spatial distribution of the electrical conductivity nonuniform, the path of the eddy currents is perturbed and the impedance of the coil which generates the AC magnetic field is modified. By measuring the impedance of this coil, a crack can hence be detected. Since the eddy currents are generated by an AC magnetic field, their penetration into the subsurface region of the material is limited by the [[Skin effect|skin effect]]. The applicability of the traditional version of eddy current testing is therefore limited to the analysis of the immediate vicinity of the surface of a material, usually of the order of one millimeter. Attempts to overcome this fundamental limitation using low frequency coils and superconducting magnetic field sensors have not led to widespread applications. | |||
A recent technique, referred to as Lorentz force eddy current testing (LET),<ref name="Zec2013"/><ref name="Uhlig2013">Uhlig, R. P., Zec, M., Brauer, H. and Thess, A. 2012 Lorentz Force Eddy Current Testing:a Prototype Model. Journal of Nondestructive Evaluation, 31, 357–372</ref> exploits the advantages of applying DC magnetic fields and relative motion providing deep and relatively fast testing of electrically conducting materials. In principle, LET represents a modification of the traditional eddy current testing from which it differs in two aspects, namely (i) how eddy currents are induced and (ii) how their perturbation is detected. In LET eddy currents are generated by providing the relative motion between the conductor under test and a permanent magnet (see figure 10). If the magnet is passing by a defect, the Lorentz force acting on it shows a distortion whose detection is the key for the LET working principle. If the object is free of defects, the resulting Lorentz force remains constant. | |||
== Advantages & Limitations == | |||
The advantages of LFV are | |||
* LFV is a non-contact techniques of flow rate measurement. | |||
* LFV can be successfully applied for such aggressive and high-temperature fluids like liquid metals. | |||
* Mean flow rate or mean velocity of fluid can be obtained without depending on flow's inhomogeneities and zones of turbulence. | |||
The limitations of the LFV are | |||
* Necessity of temperature control of measurement system because of strong dependence of magnet's magnetic field on temperature. High temperature could cause irretrievable loss of the magnetic properties of permanent magnet (Curie temperature). | |||
* Restriction of measurement zone by permanent magnet's dimensions. | |||
* Necessity of liquid level's control in case of work with open channel. | |||
* Rapid decay of the magnetic fields give rise to tiny forces on the magnet system. | |||
== See also == | |||
* [[Magnetohydrodynamics]] | |||
* [[Lorentz force]] | |||
== External links == | |||
*[http://www.tu-ilmenau.de/lorentz-force/ Official web page of Lorentz Force Velocimetry and Lorentz Force Eddy Current Testing Group] | |||
==References== | |||
{{Reflist}} | |||
[[Category:Fluid dynamics]] | |||
[[Category:Plasma physics]] | |||
[[Category:Concepts in physics]] | |||
Revision as of 19:04, 26 October 2013
Lorentz force velocimetry[1] (LFV) is a noncontact electromagnetic flow measurement technique. LFV is particularly suited for the measurement of velocities in liquid metals like steel or aluminium and is currently under development for metallurgical applications.The measurement of flow velocities in hot and aggressive liquids such as liquid aluminum and molten glass constitutes one of the grand challenges of industrial fluid mechanics. Apart of liquids, LFV can also be used to measure the velocity of solid materials as well as for detection of micro-defects in their structures.
A Lorentz force velocimetry system is called Lorentz force flowmeter (LFF). A LFF measures the integrated or bulk Lorentz force resulting from the interaction between a liquid metal in motion and an applied magnetic field. In this case the characteristic length of the magnetic field is of the same order of magnitude as the dimensions of the channel. It must be addressed that in the case where localized magnetic fields are used, it is possible to perform local velocity measurements and thus the term Lorentz force velocimeter is used.
Introduction
The use of magnetic fields in flow measurement date back to 19th century, when in 1832 Michael Faraday attempted to determine the velocity of the River Thames. Faraday applied a method in which a flow (the river flow) is exposed to a magnetic field (earth magnetic field) and the induced voltage is measured using two electrodes across the same flow. This method is the basis of the one of most successful commercial application in flow metering known as the inductive flowmeter. The theory of such devices has been developed and comprehensively summarized by Prof. J. A. Shercliff[2] in early 1950s. While inductive flowmeters are widely used for flow measurement in fluids at room temperatures such as beverages, chemicals and waste water, they are not suited for flow measurement of media such as hot, aggressive or for local measurements where surrounding obstacles limit access to the channel or pipe. Since they require electrodes to be inserted into the fluid, their use is limited to applications at temperatures far below the melting points of practically relevant metals.
The Lorentz force velocimetry was invented by the A. Shercliff. However, it did not find practical application in these early years up until recent technical advances; in manufacturing of rare earth and non rare-earth strong permanent magnets, accurate force measurement techniques, multiphysical process simulation software for magnetohydrodynamic (MHD) problems that this principle could be turned into a feasible working flow measurement technique. LFV is currently being developed for applications in metallurgy[3] as well as in other areas.[4]
Based on theory introduced by Shercliff there have been several attempts to develop flow measurement methods which do not require any mechanical contact with the fluid,.[5][6] Among them is the eddy current flowmeter which measures flow-induced changes in the electric impedance of coils interacting with the flow. More recently, a non-contact method was proposed in which a magnetic field is applied to the flow and the velocity is determined from measurements of flow-induced deformations of the applied magnetic field,.[7][8]
Principle and Physical interpretation
The principle of Lorentz force velocimetry is based on measurements of the Lorentz force that occurs due to the flow of a conductive fluid under the influence of a variable magnetic field. According to Faraday's law, when a metal or conductive fluid moves through a magnetic field, eddy currents generate there by electromotive force in zones of maximal magnetic field gradient (in the present case in the inlet and outlet zones). Eddy current in its turn creates induced magnetic field according to Ampère's law. The interaction between eddy currents and total magnetic field gives rise to Lorentz force that breaks the flow. By virtue of Newton's third law "actio=reactio" a force with the same magnitude but opposite direction acts upon its source - permanent magnet. Direct measurement of the magnet's reaction force allows to determine fluid's velocity, since this force is proportional to flow rate. The Lorentz force used in LFV has nothing to do with magnetic attraction or repulsion. It is only due to the eddy currents whose strength depends on the electrical conductivity, the relative velocity between the liquid and the permanent magnet as well as the magnitude of the magnetic field.
So, when a liquid metal moves across magnetic field lines, the interaction of the magnetic field (which are either produced by a current-carrying coil or by a permanent magnet) with the induced eddy currents leads to a Lorentz force (with density ) which brakes the flow. The Lorentz force density is roughly
where is the electrical conductivity of the fluid, its velocity, and the magnitude of the magnetic field. This fact is well known and has found a variety of applications. This force is proportional to the velocity and conductivity of the fluid, and its measurement is the key idea of LFV. With the recent advent of powerful rare earth permanent magnets (like NdFeB, SmCo and other kind of magnets) and tools for designing sophisticated systems by permanent magnet the practical realization of this principle has now become possible.
The primary magnetic field can be produced by a permanent magnet or a primary current (see Fig. 1). The motion of the fluid under the action of the primary field induces eddy currents which are sketched in figure 3. They will be denoted by and are called secondary currents. The interaction of the secondary current with the primary magnetic field is responsible for the Lorentz force within the fluid
which breaks the flow.
The secondary currents create a magnetic field , the secondary magnetic field. The interaction of the primary electric current with the secondary magnetic field gives rise to the Lorentz force on the magnet system
The reciprocity principle for the Lorentz force velocimetry states that the electromagnetic forces on the fluid and on the magnet system have the same magnitude and act in opposite direction, namely
The general scaling law that relates the measured force to the unknown velocity can be derived with reference to the simplified situation shown in Fig. 2. Here a small permanent magnet with dipole moment is located at a distance above a semi-infinite fluid moving with uniform velocity parallel to its free surface.

The analysis that leads to the scaling relation can be made quantitative by assuming that the magnet is a point dipole with dipole moment whose magnetic field is given by
where and . Assuming a velocity field for , the eddy currents can be computed from Ohm’s law for a moving electrically conducting fluid
subject to the boundary conditions at and as . First, the scalar electric potential is obtained as
from which the electric current density is readily calculated. They are indeed horizontal. Once they are known, the Biot-Savart law can be used to compute the secondary magnetic field . Finally, the force is given by
where the gradient of has to be evaluated at the location of the dipole. For the problem at hand all these steps can be carried out analytically without any approximation leading to the result
This provides us with the estimate
Conceptual setups
Lorentz force flowmeters are usually classified in several main conceptual setups. Some of them designed as static flowmeters where the magnet system is at rest and one measures the force acting on it. Alternatively, they can be designed as rotary flowmeters where the magnets are arranged on a rotating wheel and the spinning velocity is a measure of the flow velocity. Obviously, the force acting on a Lorentz force flowmeter depends both on the velocity distribution and on the shape of the magnet system. This classification depends on the relative direction of the magnetic field that is being applied respect to the direction of the flow. In Figure 3 one can distinguish diagrams of the longitudinal and the transverse Lorentz force flowmeters.

It is important to mention that even that in figures only a coil or a magnet are sketched, the principle holds for both.
Rotary LFF consists of a freely rotating permanent magnet[9] (or an array of magnets mounted on a flywheel as shown in figure 4), which is magnetized perpendicularly to the axle it is mounted on. When such a system is placed close to a duct carrying an electrically conducting fluid flow, it rotates so that the driving torque due to the eddy currents induced by the flow is balanced by the braking torque induced by the rotation itself. The equilibrium rotation rate varies directly with the flow velocity and inversely with the distance between the magnet and the duct. In this case it is possible to measure either the torque on the magnet system or the angular velocity at which the wheel spins.

Practical applications
LFV is sought to be extended to all fluid or solid materials, providing that they are electrically conductors. As shown before, the Lorentz force generated by the flow depend linearly on the conductivity of the fluid. Typically, the electrical conductivity of molten metals is of the order of so the Lorentz force is in the range of some mN. However, equally important liquids as glass melts and electrolytic solutions a have a conductivity of giving rise to a Lorentz force of the order of micronewtons or even smaller.
People are nonetheless rushing to buy properties in Singapore. A new residential condominium mission in Bedok had a long queue three days before its official launch and bought more than 350 units on the very first day. Nonetheless, there is a ‘development' that had emerged in 2011 that the majority have possibly overlooked.
In August, more than a hundred individuals across 16 states reportedly had been sickened with salmonella after consuming mangos In September, the Meals and Drug Administration detained mango imports from a Mexican packing house after the fruits had been linked to the sickenings Save Cash On Your Online Purchasing Make saving money when purchasing on-line a breeze with Bodge's favourite app, Invisible Hands. This helpful program does the price-checking analysis for you, and will warn you when a unique site has a better value - or let you realize that you have found the most effective deal. Watch Posted by Edison Foo September 29, 2013 HEARTH SALE!!! From only $9xx,000! We hope this listing will help launch your search for new properties in Singapore. It's unlawful to purchase ice cream after 6 pm, in Newark.
for a borrower with one or more excellent residential property loans3; and No SSD will be payable by the seller if the property is bought more than three years after it was bought. Non-extension of the Jan 2009 Funds assistance measures for the property market when the measures expire. Permitting up to 2 years of property tax deferral for land accepted for improvement. Lively secondary marketplace for easy exit of property investments. Curiosity on mortgage fee is tax deductible when the property is rented out. We've progressive property tax rates for residential properties- the higher the value of the residential property, the upper the tax charge. Why do I've to pay property tax on my house when I'm an onwer-occupier and not deriving rental earnings? Palacio Cluster Landed
After obtaining a Sale License (topic to authorities circumstances meant to guard individuals shopping for property in Singapore), he might www.rmmonline.com proceed to sell units in his growth. Funding in the property market of Singapore is likely one of the few investment choices the place utilizing the bank's cash could not be any easier. The power of expats, to make a down payment, leverage the capital and consequently improve total return on investment, is excessive in Singapore. PRs who own a HDB flat must sell their flat inside six months of buying a non-public residential property in Singapore. EVERLASTING residents (PRs) now face unprecedented limits on their skill to purchase property in Singapore. New Condo in 2013 March Foreigners are eligible for Singapore greenback mortgage loan. housing grant
Skilled property brokers in Singapore will assist the client and defend their interests throughout the acquisition, and will help safe the provide at the best possible price. The agents may even be sure that all paperwork are in order and that the vendor is the rightful proprietor of the property. Most of the property brokers share their databases with each other. Tuesday's measures come after the Monetary Authority of Singapore in June tightened rules on property loans, and closed loopholes that allowed some householders to circumvent loan restrictions and avoid paying levies when buying extra property. Contact us for a FREE housing loan analysis and to study concerning the newest mortgage to worth on Singapore housing loans. J Gateway Condominium (Bought Out) Oct, 2013
6. Completion of automotive park, roads and drains serving the housing project 5% 7. Notice of Vacant Possession (Upon obtaining Temporary Occupation Permit) The estimates given by SingaporeHousingLoan.SG's calculator are not quotations and are usually not binding in any way on SingaporeHousingLoan.sg or the consumer. The method of calculation does not exactly mirror that of which is being used by the individual monetary establishment and the data provided should be used as a information only. SingaporeHousingLoan.SG's calculator does not pre-qualify you for any housing loan from any monetary institution. Undercover Report Finds Unlawful Rat Meat Sold In London Market Unpasteurized Tempeh Linked To Salmonella Outbreak That Sickens 60 Hottest EC Launch in Sengkang!
BuyRentSingaporeProperty.com is dedicated in providing the newest residential launches, Developer's sales, new launches, resale, HIGH tasks and rental of properties in Singapore. Then there are new launch property condos in the mid-tier range. These are sometimes in the vicinity of the city fringe, in areas corresponding to Newton and Novena Tanjong Rhu. These new launch projects are popular due to their proximity to town heart, the place the enterprise and entertainment centers and all the amenities they provide, but they're usually cheaper than the City core region tasks. Why submit cheques to register for new property launches in Singapore? Riversails Apartment @ Higher Serangoon LakeVille @ Jurong Lakeside Condo by MCL Ferra Condo @ Leonie Hill
High Conducting media: liquid or solid metals
Among different possibilities to measure the effect on the magnet system, it has been successfully applied those based on the measurement of the deflection of a parallel spring under an applied force.[10] Firstly using a strain gauge and then recording the deflection of a quartz spring with an interferometer, in whose case the deformation is detected to within 0.1 nm. (Fig. 5 A).
Low Conducting media: Electrolytic solution or glass melts

Recent advance in LFV made it possible for metering flow velocity of media which has very low electroconductivity, particularly by varying parameters as well as using some state-of-art force measurement devices enable to measure flow velocity of electrolyte solutions with conductivity that is 106 times smaller than that for the liquid metals. There are variety of industrial and scientific applications where noncontact flow measurement through opaque walls or in opaque liquids is desirable. Such applications include flow metering of chemicals, food, beverages, blood, aqueous solutions in the pharmaceutical industry, molten salts in solar thermal power plants,[12] and high temperature reactors [13] as well as glass melts for high-precision optics.[14]
A noncontact flowmeter is a device that is neither in mechanical contact with the liquid nor with the wall of the pipe in which the liquid flows. Noncontact flowmeters are equally useful when walls are contaminated like in the processing of radioactive materials, when pipes are strongly vibrating or in cases when portable flowmeters are to be developed. If the liquid and the wall of the pipe are transparent and the liquid contains tracer particles, optical measurement techniques,[15][16] are effective enough tool to perform noncontact measurements. However, if either the wall or the liquid are opaque as is often the case in food production, chemical engineering, glass making, and metallurgy, very few possibilities for noncontact flow measurement exist.
Up to date there have been two successfully tested prototypes of metering flow velocity, both prototypes are based on deflection measurements of pendulum-like setups (Fig. 5 B). One of the experimental facilities consists of two high power (410 mT) magnets made of NdFeB suspended by thin wires on both side of channel thereby creating magnetic field perpendicular to the fluid flow, here deflection is measured by interferometer system,[17][18] (see Figures 6 a). The second setup consists of state-of-art weighting balance system from which is being hanged optimized magnets on the base of Halbach array system. While the total mass of both magnet systems are equal (1 kg), this system induces 3 times higher system response due to arrangement of individual elements in the array and it’s interaction with predefined fluid profile. Here use of very sensitive force measuring devices is desirable, since flow velocity is being converted from the very tiny detected Lorentz Force. This force in combination with unavoidable dead weight of the magnet () is around .

Lorentz force sigmometry

Lorentz force sigmometry (LOFOS)[19] is a contactless method for measuring the thermophysical properties of materials, no matter whether it is a fluid or a solid body. The precise measurements of electrical value, density, viscosity, thermal conductivity and surface tension of molten metals are in great importance in industry applications. One of the major problems in the experimental measurements of the thermophysical properties at high temperature (>1000 K) in the liquid state is the problem of chemical reaction between the hot fluid and the electrical probes. The basic equation for calculating the electrical conductivity is derived from the equation that links the mass flow rate and Lorentz force generated by magnetic field in flow:
where is the specific electrical conductivity equals to the ratio of the electrical conductivity and the mass density of fluid . is a calibration factor that depends on the geometry of the LOFOS system.
From equation above the cumulative mass during operating time is determined as
where is the integral of Lorentz force within the time process. From this equation and considering the specific electrical conductivity formula, one can derive the final equation to compute the electrical conductivity for the fluid, in the form
Time-of-flight Lorentz force velocimetry

Time-of-flight Lorentz force velocimetry,[20][21] is intended for contactless determination of flow rate in conductive fluids. It can be successfully used even in case when such material properties as electrical conductivity or density are not precisely known under specific outer conditions. The last reason makes time-of-flight LFV especially important for industry application. According to time-of-flight LFV (Fig. 9) two coherent measurement systems are mounted on a channel one by one. The measurement is based on getting of cross-correlating function of signals, which are registered by two magnetic measurement’s system. Every system consists of permanent magnet and force sensor, so inducing of Lorentz force and measurement of the reaction force are made simultaneously. Any cross-correlation function is useful only in case of qualitative difference between signals and for creating the difference in this case turbulent fluctuations are used. Before reaching of measurement zone of a channel liquid passes artificial vortex generator that induces strong disturbances in it. And when such fluctuation-vortex reaches magnetic field of measurement system we can observe a peak on its force-time characteristic while second system still measures stable flow. Then according to the time between peaks and the distance between measurement system observer can estimate mean velocity and, hence, flow rate of the liquid by equation:
where is the distance between magnet system, the time delay between recorded peaks, and is obtained experimentally for every specific liquid, as shown in figure 9.
Lorentz force eddy current testing

A different, albeit physically closely related challenge is the detection of deeply lying flaws and inhomogeneities in electrically conducting solid materials.
In the traditional version of eddy current testing an alternating (AC) magnetic field is used to induce eddy currents inside the material to be investigated. If the material contains a crack or flaw which make the spatial distribution of the electrical conductivity nonuniform, the path of the eddy currents is perturbed and the impedance of the coil which generates the AC magnetic field is modified. By measuring the impedance of this coil, a crack can hence be detected. Since the eddy currents are generated by an AC magnetic field, their penetration into the subsurface region of the material is limited by the skin effect. The applicability of the traditional version of eddy current testing is therefore limited to the analysis of the immediate vicinity of the surface of a material, usually of the order of one millimeter. Attempts to overcome this fundamental limitation using low frequency coils and superconducting magnetic field sensors have not led to widespread applications.
A recent technique, referred to as Lorentz force eddy current testing (LET),[22][23] exploits the advantages of applying DC magnetic fields and relative motion providing deep and relatively fast testing of electrically conducting materials. In principle, LET represents a modification of the traditional eddy current testing from which it differs in two aspects, namely (i) how eddy currents are induced and (ii) how their perturbation is detected. In LET eddy currents are generated by providing the relative motion between the conductor under test and a permanent magnet (see figure 10). If the magnet is passing by a defect, the Lorentz force acting on it shows a distortion whose detection is the key for the LET working principle. If the object is free of defects, the resulting Lorentz force remains constant.
Advantages & Limitations
The advantages of LFV are
- LFV is a non-contact techniques of flow rate measurement.
- LFV can be successfully applied for such aggressive and high-temperature fluids like liquid metals.
- Mean flow rate or mean velocity of fluid can be obtained without depending on flow's inhomogeneities and zones of turbulence.
The limitations of the LFV are
- Necessity of temperature control of measurement system because of strong dependence of magnet's magnetic field on temperature. High temperature could cause irretrievable loss of the magnetic properties of permanent magnet (Curie temperature).
- Restriction of measurement zone by permanent magnet's dimensions.
- Necessity of liquid level's control in case of work with open channel.
- Rapid decay of the magnetic fields give rise to tiny forces on the magnet system.
See also
External links
References
43 year old Petroleum Engineer Harry from Deep River, usually spends time with hobbies and interests like renting movies, property developers in singapore new condominium and vehicle racing. Constantly enjoys going to destinations like Camino Real de Tierra Adentro.
- ↑ 1.0 1.1 1.2 Thess, A., Votyakov, E. and Kolesnikov, Y. Lorentz Force Velocimetry. Phys. Rev. Lett. 96, 2006
- ↑ Arthur J. Shercliff: Theory of Electromagnetic Flow Measurement. Cambridge University Press, ISBN 978-0-521-33554-6.
- ↑ Y. Kolesnikov, C. Karcher, A. Thess, Lorentz Force Flowmeter for Liquid Aluminum: Laboratory Experiments and Plant Tests (in German), Metall. Mat. Trans. B 42B (2011) pp. 241-250., doi:10.1007/s11663-011-9477-6
- ↑ http://www.tu-ilmenau.de/lorentz-force/
- ↑ J. Priede, D. Buchenau., G. Gerbeth, Contactless Electromagnetic Phase-Shift Flowmeter for Liquid Metals, Measur. Sci. Tech. 22 (2011) 055402,2011
- ↑ 6.0 6.1 A. Thess et al., Theory of the Lorentz force flowmeter, 2007 New J. Phys. 9 299
- ↑ J. Baumgartl, A. Hubert, and G. M¨uller , The use of magnetohydrodynamic effects to investigate fluid flow in electrically conducting melts, Phys. Fluids A 5, 3280 (1993)
- ↑ Stefani F., Gundrum T., Gerbeth G., Contactless inductive flow tomography,Phys Rev E 70,056306 (2004)
- ↑ J. Priede, D. Buchenau., G. Gerbeth, Single-Magnet Rotary Flowmeter for Liquid Metals, J. Appl. Phys. 110 (2010) pp. 03451., doi:10.1063/1.3610440
- ↑ C. Heinicke et al., Interaction of a small permanent magnet with a liquid metal duct flow. Journal of Applied Physics (2012) 112
- ↑ Wegfrass, A. et al., A universal noncontact flowmeter for liquids. Applied Physics Letters, 100 (2012)
- ↑ U. Herrmann, B. Kelly, and H. Price, Energy 29, 883–893 (2004)
- ↑ C. W. Forsberg, P. F. Peterson, and P. S. Pickard, Nucl. Technol. 144, 289 (2003)
- ↑ U. Lange and H. Loch, “Instabilities and stabilization of glass pipe flow” in Mathematical Simulation in Glass Technology, Schott Series on Glass and Glass Ceramics, edited by D. Krause and H. Loch (Springer Verlag, 2002)
- ↑ C. Tropea, A. L. Yarin, and J. F. Foss, Handbook of Experimental Fluid Mechanics, Springer-Verlag, GmbH, 2007
- ↑ F. Durst, A. Melling, and J. H. Whitelaw, Principles and Practice of Laser-Doppler Anemometry, 2nd ed. Academic, London, 1981
- ↑ Wegfrass, A. et al. Flow rate measurement of weakly conducting fluids using Lorentz force velocimetry Meas. Sci.Technol. 23 105307 (2012), http://stacks.iop.org/MST/23/105307
- ↑ 18.0 18.1 C. Diethold and F. Hilbrunner, Force measurement of low forces in combination with high dead loads by the use of electromagnetic force compensation, Meas. Sci. Technol. 23, 074017 (2012), http://iopscience.iop.org/0957-0233/23/7/074017/
- ↑ Uhlig, R. P., Zec, M., Ziolkowski, M., Brauer, H. and Thess, A. 2012 Lorentz force sigmometry: A contactless method for electrical conductivity measurements. Journal of Applied Physics, 111
- ↑ 20.0 20.1 Jian, D. and Karcher, C. 2012 Electromagnetic flow measurements in liquid metals using time-of-flight Lorentz force velocimetry. Measurement Science and Technology, 23
- ↑ A. Viré, B. Knaepen, and A. Thess, Lorentz force velocimetry based on time-of-flight measurements, Phys. Fluids 22, 125101 (2010)
- ↑ 22.0 22.1 M. Zec et al., Fast Technique for Lorentz Force Calculations in Nondestructive Testing Applications, COMPUMAG 2013, Budapest, Hungary
- ↑ Uhlig, R. P., Zec, M., Brauer, H. and Thess, A. 2012 Lorentz Force Eddy Current Testing:a Prototype Model. Journal of Nondestructive Evaluation, 31, 357–372